Figure 1-12.  Fail Circuit Schematic Diagram
Up
TM-10-6665-297-13P Bacharach Combustibles Gas Alarm System NSN 6665-00-410-4982 Manual
Next
Figure 1-13.  CD800/830 Relay External Circuits and Typical External Connections

TM 10-6665-297-13&P 1-3.1.8   Alarm and Warning Reset Circuits (continued) CD802/832  relays  K2,  K3,  and  K4  latch  and  reset  in  the  same  way  as  K1  and  K2  of  the  CD800/830 control modules. Circuit  modifications  for  remote  resetting,  or  for  automatic  resetting  of  warning  and  alarm  relays  as alarm  conditions  are  cleared  may  be  accomplished,  if  desired,  during  or  after  the  installation  of  a system. (See Subsection 2-7. ) A common reset button for several modules may be provided, in which case individual reset switches would not be incorporated in the system. Kits for conversion to common reset are available for systems with standard individual control module reset connections. 1-3.1.9   Display  Meter.  The  display  meter,  located  on  the  front  panel  of  the  control  module,  continuously indicates  gas-to-air  mixtures  at  the  remote  detect-  or  in  terms  of  percentage  of  the  lower  explosive limit.  With  fresh  air  at  the  detector,  the  indicator  reads  zero.  But  catalytic  oxidation  of  gas  on  the detector sensor produces unequal outputs from the two halves of the detector circuit, which causes a differential amplifier (U3 for CD800/830; U1 for CD802/832) in the control unit to amplify the difference and produce a proportionate current flow through the indicating meter (Figure 1-12). The  CD802/832  module  meter  responds  either  to  the  channel  selected  by  the  setting  of  the  channel selector control, or, if the control is set to AUTO, to the channel with the strongest signal. In addition to the mechanical adjustment-to-zero screw on the meter front, two electrical adjustments prepare the meter for proper indication of gas air mixtures. A ZERO potentiometer (CD800/830: R24; CD802/832: R9, R13) screw adjustment (Figures 1-4, 1-5, 1-9) serves to balance the input voltage to amplifier U3 (with detector in fresh-air or nitrogen-inerted condition for setting), to assure that the output signal  fed  to  the  meter  is  zero.  After  the  indicator  has  thus  been  set  to  zero,  a  GAIN  potentiometer (CD800/830: R10; CD802/832: R22) screw adjustment (Figures 1-4, 1-5, 1-9) provides the amount of amplification gain required to drive the indicator needle full-scale in the presence of a 100-percent L. E. L. gas-air mix at the detector. Because each combustible gas has its own rate of heat energy release upon  oxidation,  the  GAIN  adjustment  must  be  set  with  respect  to  the  kind  or  kinds  of  gas  to  be monitored. 1-3.1.10Relay External Circuits. (Figures 1-13, 1-14) Solenoid operated contacts for controlling external lamps, buzzers, horns, fans, sprinklers, door closers, etc., are provided by control unit relays K1, K2, and K3 for all models, and an additional relay K4 for CD802/832 dual-channel models. Warning relay K1 and alarm  relay  K2  of  CD800/830  models,  and  warring  relay  K2  of  CD-  802/832  models  each  have  two isolated normally open contacts and two 23-9617 7/1/76 1-20