Click here to make tpub.com your Home Page

Page Title: Figure 1-14. Static Mode, Internal Power, Cool Mode, NBC Off
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Back
Figure 1-13. Static Mode, Internal Power, Cool Mode, Full NBC
Up
TM-10-5410-228-24 Chemical Biologiocal Protective Shelter (CBPS) System NSN 5410-01-441-8054 (Green) (EIC:5ZT) NSN 5410-01-482-4633 (Tan) Manual
Next
Figure 1-15. Static Mode, Internal Power, Cool Mode, Rib Fan On, Full NBC

TM 10-5410-228-24
1.16.6 Static Mode, Internal Power, Cool Mode, NBC Off.
Placing the control switches in the position corresponding the the above modes opens solenoid valves SV2
and SV6 and closes solenoid valve SV9 and valve PD1 by applying +24 Vdc to the coils. This allows some
portion of the total hydraulic fluid flow to bypass the NBC fan motor, M3. Flow control valve FP2 is used to
regulate the flow and hence the speed of the NBC fan motor whenever the control switches are in the non-
NBC mode. All other functions are as previously described.
Valve
SV1
SV2
SV4
SV5
SV6
SV7
SV8
SV9
Energized State
OFF
ON
ON
OFF
ON
OFF
OFF
ON
Position
Closed
Open
Open
Closed
Open
Open
Closed
Closed
Figure 1-14. Static Mode, Internal Power, Cool Mode, NBC Off

Privacy Statement - Press Release - Copyright Information. - Contact Us