Page  Title: Figure 1-14. Use of IIW Block to Check Entry Surface Resolution
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

Back
Back Surface Resolution
Up
TM-1-1500-335-23 Nondestructive Inspection Methods Manual
Next
Figure 1-15.  Straight Beam Distance Calibration with IIW Block

T.O. 33B-1-1 Figure 1-14. Use of IIW Block to Check Entry Surface Resolution 1.8.2.4.3 Checking Entry Surface Resolution with ASTM Blocks. a. Use  an  ASTM  block  with  a  #5  FBH,  or  other  size  if  specified.    Choose  a  block  with  a  metal  travel distance according to the frequency being used (see Table 1-8). b. Maximize the separation between the initial pulse and the hole signal. c. Check  that  the  hole  signal  is  actually  the  indication  of  the  first  echo  from  the  hole  by  noting  the position  of  the  hole  signal  on  the  calibrated  distance  scale  of  the  waveform  display.    The  distance should be the actual depth of the hole. d. Evaluate the waveform patterns. 1.8.2.5 Distance Calibration of A Scan. 1.8.2.5.1 Straight Beam Distance Calibration for Weld Inspection (IIW Block). a. Position the search unit on an IIW block at P-1, P-2 or P-3 as shown in Figure 1-15.  This distance between multiple back ref lections is as follows: (1) 1.00 inch at P-1 (2) 4.00 inch at P-2 (3) 8.00 inch at P-3 1-62 Change 2