Page  Title: Testing Lipophilic Emulsifier
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

Back
Testing Of Material in Use
Up
TM-1-1500-335-23 Nondestructive Inspection Methods Manual
Next
Testing Hydrophilic Remover

T.O. 33B-1-1 1-35 (9) Using tweezers, insert a quartered piece of filter paper into the cylinder mixture, withdraw the paper and set it aside to air dry. (10) When both filter papers (reference and in-use) are dry, compare the fluorescent brightness of the filter papers to each other under a blacklight.  If a significant difference of fluorescent brightness is noted, the fluorescent properties of the in-use production line penetrant have deteriorated, and the fluorescent sensitivity will probably not be acceptable.  Follow accepted activity standards to process and perform additional testing or to discard the contaminated/degraded material. (11) At the conclusion of the fluorescent brightness testing, clean the cylinder with acetone (Specification 0-A-51F), rinse with water, and again clean with acetone.  Dry with clean filtered compressed air. c.     Rapid  Brightness  Test  (Field).    A  rough  check  of  penetrant  baths  can  be  accomplished  by  comparing their  appearance  on  an  absorbent  material,  preferably  the  filter  paper  used  in  paragraph  1.5.5.2.2b above.  Place a drop of the working bath penetrant on a paper towel.  Place a second drop of penetrant from the reference standard near the drop from the working bath.  When the two drops merge, examine under a black light for difference in color and brightness. 1.5.5.3 Testing Lipophilic Emulsifier. Penetrant is an unavoidable contaminant of lipophilic emulsifier.  It is carried into the emulsifier on the surface of parts where  it  dissolves  and  is  washed  off  during  immersion  and  drain.    Since  emulsifier  and  penetrant  are  miscible  in  all concentrations,   even   small   quantities   of   fluorescent   dye   will   cause   the   emulsifier   to   fluoresce.      The   fluorescent brightness  increases  with  increasing  dye  content,  but  it  is  impossible  to  visually  estimate  penetrant  contamination  by observation of the tank surface. 1.5.5.3.1 Emulsifier  will  continue  to  function  when  contaminated  with  penetrant;  however,  when  the  penetrant  concentration reaches  a  certain  level,  the  emulsification  action  slows  and  eventually  stops.    The  military  procurement  specification requires  a  4  to  1  mixture  of  emulsifier  to  penetrant  to  leave  no  more  residual  background  than  the  uncontaminated emulsifier. 1.5.5.3.2 Removability Test. NOTE Grit  blasting  using  100  mesh  aluminum  oxide  grit  is  required  only  on  locally manufactured   panels   to   roughen   the   surface   and   is   only   required   one   time. Normally ultrasonic cleaning or solvent cleaning is performed after grit blasting. a.     In-use lipophilic emulsifiers SHALL be periodically tested for contamination.  A two-inch by four inch, 16  gauge  (0.060")  annealed  type  301  or  302  stainless  steel  panel  is  required.    The  panel  SHALL  be ultrasonically  cleaned  or  vapor  degreased  and  grit  blasted  on  both  sides  using  100  mesh,  aluminum oxide  grit  (not  beads),  using  60  psig  air  pressure,  with  the  gun  held  normal  to  and  approximately  18 inches  from  the  panel  surface.    After  blasting,  the  panel  surface  should  be  handled  by  the  edges  only and protected from contamination by wrapping in tissue paper. b.    Immerse the panel in the working penetrant bath and allow it to drain for 10 minutes at approximately a  60°  (±15°)  angle.    At  the  end  of  the  drain  period  apply  working  bath  emulsifier  to  one  half  of  the panel  and  reference  standard  emulsifier  to  the  other  half.    Application  may  be  either  by  pouring  or immersion.    If  pouring  is  used,  place  a  small  quantity  of  both  working  bath  emulsifier  and  reference standard  emulsifier  into  separate  containers  that  are  suitable  for  pouring.    Apply  the  emulsifier  to  the upper edge of the panel so it flows down across half of the panel face.  This shall be done with the panel in an upright position.  It is desirable to have the two emulsifier strips close together at the center of the

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing