TM 9-1240-380-34
PROTECTIVE PLUG, CLAMP, WIRE, SLEEVE ASSEMBLY, CONTACT
6-20.
(ELECTRICAL), AND CONNECTOR INSTALLATION (CONT)
FRAME 1
Procedure
Step
1.
Thread wire (1) through holes in elbow assembly (2).
2.
Using drift pin and hammer, install connector (3) in elbow assembly (2) and align hole
in connector with setscrew hole.
3.
Using 1/16" Allen wrench, install two setscrews (4) in elbow assembly (2) to fasten
connector (3).
4.
Put sealing compound on all surfaces of plug (5) (JPG).
5.
Using spanner wrench, install plug (5).
Be careful not to damage mirror (6). Do not get
fingerprints or smears on mirror surfaces.
6.
Using tweezers, thread wire (1) behind mirror (6).
7.
Using your hand, screw sleeve assembly (7) onto elbow assembly (2).
8.
Using tweezers, thread wire (1) through sleeve assembly (7).
9.
Using soldering iron and solder, solder wire (1) to contact (8) (JPG) with slots and
raised portion facing out.
10.
Using tweezers, pull wire (1) back through sleeve assembly (7) until contact (8) is
seated.
Using 3/16" flat tip screwdriver, hold down wire (1) with two clamps (9) and two
11.
screws (10).
GO TO FRAME 2
Vol II
6-34