Click here to make tpub.com your Home Page

Page Title: Replacing open lead-acid batteries in vehicles and equipment with sealed lead-acid batteries.
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Back
Replacing open lead-acid batteries in vehicles and equipment with sealed lead-acid batteries.
Up
TM-9-6140-200-14 Lead-Acid Storage Batteries Manual
Next
Replacing open lead-acid batteries in vehicles and equipment with sealed lead-acid batteries - continued



TM 9-6140-200-14
NOTE
Do not mix vented and sealed lead-acid batteries in one vehicle,
When replacing all open lead-acid batteries with Sealed Lead Acid
batteries replace as a set. Do not mix.
Since the sealed lead-acid battery's is " maintenance free" its periods
between inspection are longer. It is necessary to clean the battery
compartment and carefully make the electrical connections before
installing sealed lead-acid batteries.
The same applies to accurate adjustment of the voltage regulator;
The voltage regulator must operate in the band applicable to the
vehicle or equipment concerned. The aim should be to attain the
lower voltage tolerance limit (see equipment TM).
Do not believe that increasing the voltage brings any advantages.
Quite the opposite is true. The batteries will be over-charged or fail
prematurely.
5. When open lead-acid batteries are to be replaced by sealed lead-acid batteries,
carry out the following action in the order given.
a. Remove open lead-acid batteries; check with lead-acid battery tester (item
20 or 22, Appx. B) to determine whether they are suitable for other possible
uses.
b. Use the same voltage values to assess criteria for corresponding types of
battery.
c. Thoroughly clean the battery compartment and hold downs. Repair or
replace any damaged parts. Thoroughly clean and remove any residual
grease.
6. Put the sealed lead-acid batteries into operation (see paragraph 5-1).
7. Install the sealed lead-acid batteries.