Section III. TESTING PROCEDURES
Up
TM-11-6625-2631-14 Test Sets Battery TS-2530/UR Manual
Next
Figure 7-1. Test Set, Battery TS-2530A/UR



TM 11-6625-2631-14
DIFFERENCE DATA
D I F F E R E N C E DATA SHEET
TS-2530A/UR
Test SET, BATTERY
(NSN 6625-00-238-0223)
THE INFORMATION CONTAINED IN CHAPTERS 1 THROUGH 6 AND APPENDIXES B AND C OF THIS
TECHNICAL MANUAL ARE APPLICABLE TO THIS MODEL EXCEPT FOR THE DIFFERENCES
CITED IN THIS DIFFERENCE DATA SHEET
cable red lead between red lead termination cap and
7 - 1 . Introduction
PRC-63 and URT-21 positive (+) connector on the
Test Set, Battery TS-2530A/UR (fig. 7-1) is the same
front panel. Check continuity of test cable black lead
as the TS-2530/UR except that the TS-2530A/UR does
between black lead termination cap and PRC-63 and
not require the use of the MX-8801/PRC-80 for testing
URT-21 negative (-) connector on the front panel.
battery used in the AN/PRC-90. For the Ts-2530A/UR
the URC-10 battery test connector cable has been
7-5. Functioning of Equipment
removed and replaced with a hard wired-in test cable
Same as far TS-2530/UR  except fur changes in block
for testing Battery BA-1568/U used in the
diagram and schematic diagram as shown in figures
AN/PRC-90. The red lead (postive) and black lead
7-2 and 7-8.
(negative) of this cable are terminated with plastic
7-6. General Support Maintenance
molded cups which are used to connect the battery
Same as for TS-2530/UR except for the following
being tested.
a. Test able of TS-2530A/UR is used in place of
7-2. Service Upon Receipt and Installation
MX-8801/PRC-90 for operational test of PRC-90 bat-
Same as for TS-2530/UR, except test cable is used in
tery.
place of MX-8801/PRC-90.
b. When replacing TS-2530/UR test cable, use grom-
met part No. A1-18-0257-3 and test cable part No. A3-
7-3. Operating Instructions
06-0511.
Same as for TS-2530/UR except cable is used in
place of MX-8801/PRC-90. Also the following updated
7 - 7 . Appendix B. Maintenance Allocation
battery test information applies to  both modles when
Same as for TS-2530/UR except TS-2530A/UR test ca-
testing Battery BA-1568/U:
ble is used in place of MX-8801/PRC-90.
a.The PRC-90 battery data card is not to be used
7-8. Appendix C. Organizational, Direct
Test meter reading given in b below is used to deter-
Support,  and  General
mine if battery tested is considered acceptable far
Support  Maintenance
further use.
Repair Parts and Spe-
b. Meter reading below 0.74 indicated a weak
c i a l Tools List
BA-1568/U battery and these batteries should be re-
Same as for TS-2530/UR except that TS-2530A/UR
jected. Meter reading of 0.74 and above indicates an
used grommet part No. A1-18-0257-3 and test cable
acceptable BA-1568/U battery.
part No. A3-06-0511.
7-4.
Organizational
Maintenance
lnstruc-
tions.
7-9. Illustrations
The following figures 7-1, 7-2, and 7-8 apply to
Same as for TS-2530/UR except for continuity check
TS-2530A/UR only:
of TS2530A/UR test cable. Checck continuity of test
Change 1