![]() ![]() TM 11-6130-413-12
WARNINGS
BATTERY SHOP SAFETY PRACTICES
Nickel-cadmium battery maintenance personnel should be thoroughly trained in
the use of charging, discharging, and test procedures. The employment of proper-
ly trained personnel in the maintenance of nickel-cadmium batteries cannot be
overemphasized. The nickel-cdmium battery shop must be used ONLY to main-
tain nickel-cadmium batteries. Anything associated with lead-acid batteries
should never come in contact with nickel-cadmium batteries, including acid
fumes. In addition to the equipment required to maintain nickel-cadmium batter-
ies; the nickel-cadmium battery shop should have adequate ventilation; deluge
shower, eyewash fountain, and fire extinguisher (CO2).
TIGHTENING TERMINAL SCREWS AND STUDS
Be extremely careful when tightening terminal screws and studs. Bodily injury
and damage to the equipment may result if the torque wrench accidentally causes
a short circuit.
d
|
|