Figure 4-2. Pin and Terminal Locations for Components Replaced at General Support Level (Sheet 2 of 4)
sure S6 is actuated (in down and closed position)
0.04-0.08 inch coating of red staking compound
when measurements are made.
(SM-A-852314) on S1 and on T1 terminals 1 through
5. Go to section V.
(1) If continuity is good; go to step f.
(2) If continuity is not good; replace S1 (Sec-
(2) If continuity not good; replace S6 (Section
tion IV, para 4-21), apply a 0.04-0.08 inch coating of
IV, para 4-20).
red staking compound (SM-A-852314) on T1 termi-
f. Peel or pick away red staking compound on
nals 1 through 5. Go to section V.
CB1 (fig. 4-1 and 4-2). Check for continuity between
e. Peel or pick away red staking compound on S6
CB1-2 and CB1-1, and between CB1-4 and CB1-3.
Make sure POWER switch is in ON position for this
S6A-C to S6A-NO and between S6B-C and S6B-NO
measurement.
(only two wires each side of interlock switch). Make
(1) If continuity is good; go to step g.
4-9
|
|