Click here to make tpub.com your Home Page

Page Title: Table 3-5. Performance Test Procedures
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Back
Section V. DIRECT SUPPORT TESTING PROCEDURE
Up
TM-11-6130-392-34 Charger Battery PP-7286/U Manual
Next
Switch



TM 11-6130-392-34
Table 3-5. Performance Test Procedures - Continued
Column 3
Column 2
Column 1
Reference, or Instruction
Acceptable Test Result
Test Procedure
Display reads . 0 when START TIME is
(10) S e t C H A R G E T I M E H O U R S
pressed, goes blank when START TIME
R E M A I N I N G to read 0 0 . 0 . Press
is released.
START TIME switch. Check display.
No current flow.
(11) Check panel meter.
Display is 9.9.
(12) Set CHARGE TIME HOURS RE-
Press
MAINING  to  read  09.9.
START TIME switch. Check display.
Display is .9.
(13) S e t C H A R G E T I M E H O U R S
R E M A I N I N G to read 0 0 . 9 . Press
START TIME switch. Check display.
Display is same, for each of the 8 different
(14) Repeat, as in (13), with settings at:
settings.
17.7
16.6
15.5
14.4
13.3
12.2
11.1
10,0
For each, check display.
Display did not change: reads 18.8.
(15) Set CHARGE TIME HOURS RE-
Press
MAINING  to  read  18.8.
START TIME switch. Remove power
cable from 115 VAC input source. Use
stopwatch; time 10 seconds and recon-
nect power cable. Check display.
Go to step (17) table 3-4.
All tests were passed . . . . . . . . . . . . . . . . .
(16) If performance tests are now com-
pleted, turn POWER switch to OFF.
Remove power cable from 115 VAC
source. Remove band from interlock
switch and remove clip leads from
REMOTE BATTERY jacks. Assem-
ble retainer and cover and set con-
trols per para 3-10e. Refer to figure
3-1.
POWER ON lamp lights.
(17 Connect power cable to 115 VAC. Set
POWER switch to ON. POWER ON
lamp should light.
(18) Set POWER OFF, disconnect power
cable, return battery charger to serv-
ice.
Section VI. MAINTENANCE OF BATTERY CHARGING TRAY ASSEMBLY
3-22. Connector
3-21. General
Removal and installation of any connector (1, fig. 2-1.1)
Repair of battery charging tray assembly at direct
is as follows:
support level is limited to replacement of items
listed in paragraph 3-3.
a. Note and record the connector terminals
from which the wiring is to be removed, then un-
WARNING
solder the wiring from rear of socket.
Disconnect cable assembly (7, fig. 2-1.1) from
b. Unscrew the hex nut from rear of defective
b a t t e r y charger  b e f o r e p e r f o r m i n g a n y
connector and remove connector and terminal
m a i n t e n a n c e on the battery charging tray
washer.
assembly.
3-22 Change 1


Privacy Statement - Press Release - Copyright Information. - Contact Us