Fault Isolation Tests - continued
Up
TM-11-6130-392-34 Charger Battery PP-7286/U Manual
Next
Section IV. MAINTENANCE OF BATTERY CHARGER



TM 11-6130-392-34
Figure 3-8. Charging Module (Assemblies A6 - A10) Terminal and Test Point Locations
POWER to OFF. Go to step k.
send battery charger to next higher maintenance
k. Connect oscilloscope probe to A11-TP5, and
level.
connect return lead to A11-TP6. Set oscilloscope
(2) If all fuses are faulty; replace F1 (fig. 2-2)
control to trigger internally from a positive 10 VDC
only and set CHANNEL SELECT switch to 1.
pulse.
f. S e t P O W E R t o O N . P r e s s S T A R T T I M E
l. S e t P O W E R t o O N . P r e s s S T A R T T I M E
switch. Check panel meter.
switch. Waveform will show on oscilloscope each
( 1 ) If panel meter shows current flow; set
time START TIME switch is pressed. Press START
POWER to OFF, replace fuses F2 through F5 (fig.
TIME a few times; check waveform, to be same as
2-2). Go to section V.
(2) If panel meter shows no current flow; dis-
(1) If waveform (fig. 3-5) is same A12 is good;
c o n t i n u e testing, s e n d b a t t e r y c h a r g e r t o n e x t
set POWER to OFF, replace A11 (refer to Section
higher maintenance level.
IV, para 3-15). Go to section V.
g. Set POWER to OFF. Remove multimeter posi-
(2) If waveform is not the same as figure 3-5;
tive (+) lead from A9-TP4. Remove extender board,
set POWER to OFF, remove probe from A11-TP5.
put A9 back in original location (fig. 3-2).
m. Remove extender board. Return A11 power
h. Refer to paragraph 3-9b. and put power supply
supply assembly to original location (fig. 3-2). Refer
assembly All (fig. 3-2) on extender board.
i. Set multimeter to 10 VDC scale. Connect posi-
to paragraph 3-9b. and put timing circuit assembly
A12 (fig. 3-2) on extender board.
tive lead of multimeter to A11-TP2 (fig. 3-4).
n. Connect oscilloscope probe to pin 31 on A12
j. S e t P O W E R t o O N . P r e s s S T A R T T I M E
extender board. Connect return lead to pin 36. Set
switch. Check multimeter reading.
POWER to ON; press START TIME switch, check
(1) If meter reading is 7.0 VDC or more; dis-
c o n t i n u e testing, s e n d b a t t e r y c h a r g e r t o n e x t
o s c i l l o s c o p e waveform (fig. 3-5). Press START
higher maintenance level.
TIME switch a few times. Compare waveform on
oscilloscope, to figure 3-5.
(2) If meter reading is less than 7.0 VDC: set
3-15