WARNINGS
HIGH VOLTAGE is used in the operation of this equipment. DEATH ON CONTACT
may result if personnel fail to observe safety precautions. The power cable, interlock
switch, POWER switch, EMI filters, filter capacitor, and the power transformer with
their associated wiring are components in the battery charger which may have high
voltage on exposed terminals. Before working inside the equipment, set the POWER
switch to OFF and remove the power cable from the power source. Ground high
voltage points before touching them.
Dangerous fumes or gases may be generated during battery charging operations. Be
sure the working area has adequate ventilation. Do not allow smoking or open flame
near charging batteries; vented gas may explode. Do not attempt to charge a damaged
or leaking battery.
Adequate ventilation should be provided while using TRICHLOROTRIFLUOROE-
THANE. Prolonged breathing of vapor should be avoided. The solvent should not be
used near heat or open flame; the products of decomposition are toxic and irritating.
Since TRICHLOROTRIFLUOROETHANE dissolves natural oils, prolonged contact
with skin should be avoided, When necessary, use gloves which the solvent cannot
penetrate. If the solvent is taken internally, consult a physician immediately.
If the battery charger is to be prepared for shipment or placed in inactive storage for
more than 30 days, remove the memory battery (B1).