![]() ![]() TB 43-0134
See Appendix F for deactivation of THR batteries.
(3) NOTE on turn-in documentation that these
h.
Disposition and Disposal DO NOT accumulate
batteries may contain ASBESTOS.
d.
Handling. See para 2-3.
and store waste batteries for disposal for more than 90 days.
e.
Fire control/suppression.
See para 2-7. THR batteries MUST be deactivated prior to
disposition and disposal.
WARNING
(1) Dispose THR batteries as HW in
Halon fire extinguishers SHALL NOT be
accordance with RCRA regulations. Disposition may be
used to combat fires involving THR bat-
through the local servicing DRMO, or via local contract, with an
teries.
EPA HW# of D007 for chromium.
A C02 fire extinguisher is recommended. See para 2-4.
(2) THR batteries have not been tested under
f.
Storage. See para 2-5.
bioassay requirements. Disposition may be through the local
g.
Transportation requirements.
servicing DRMO, or via local contract, due to chromium
See para 2- for packaging, marking and labeling requirements.
content.
Not regulated under Title 49 CFR, Part 172.101 HMT. THR
batteries MUST be deactivated prior to shipping for disposal.
4-15
|
|