Section V. TECHNICAL DATA AND SERVICE LIFE



TB 11-6135-200-25
(F)  Less than palletized load.  When quantities of
strapping or pressure-sensitive filament tape banding
conforming to PPP-S-760, type 11 and PPP-T-97, type
Battery BA-487A/U per destination are less than a pallet
IV respectively; selection of the material and application
load the item packaged as specified in (a) through (d)
shall be in accordance with the appendix of the
above, shall be waterproofed with tape conforming to
applicable box specification.
PPP-T-76 in accordance with the taping requirements of
the appendix to the box specification.  A quantity of
(3) Level C. Battery BA-487/U shall be packaged in
waterproofed containers shall be placed within a
accordance with items I through 6 of chart in b below and
closefitting box conforming to PPP-B-601, overseas type;
figure 10 except the fiberboard box and cells shall be
PPP-B-621, style 4, class 2; or PPP-B-585, style 2 or 3,
class domestic. Box closure shall be in accordance with
class 3. When the gross weight exceeds 200 pounds or
the appendix to the box specification.
the container length and width is 48 x 24 inches or more
and the weight exceeds 100 pounds, 3 x 4 inch skids,
(a)  Palletized load.  A quantity of Battery BA-487/U,
laid flat, shall be applied in accordance with the
requirements of the container specification or if not
packaged as specified in (1) (a) through (d), shall be
mentioned in the specification in a manner which will
palletized as specified in (1) (e) except that the
adequately support the item and facilitate the use of
fiberboard' caps shall be class domestic.
material handling equipment.  Closure and strapping
(b) Less than palletized load. When quantities of Battery
shall be in accordance with the applicable container
specification or appendix thereto except that the metal
BA-487/U per destination are less than a pallet load, a
strapping shall conform to QQ-S-781, type 1, class B.
quantity of batteries, packaged as specified in (1) (a)
through (d) shall be packed as specified in (1) (J) except
(2) Level B.
that the fiberboard boxes shall conform to PPPB-640 and
PPP-B-636, class I and class domestic respectively; and
(a) Palletized load. A quantity of Battery BA-487A/U,
reinforcing shall not be required for boxes conforming to
packaged as specified in (1) (a) through (d) above, shall
PPP-B-636.
be palletized as specified in (1) (e) above.
(4)  Packing.  Packing shall be level A, B or C, as
(b) Less than palletized load. When quantities of Battery
specified.  Shipping containers for all levels shall be
BA-487A/U per destination are less than a pallet load, a
capable of stacking and supporting superimposed loads
quantity of batteries, packaged as specified in (1) (a)
during shipment and storage without damaging the
through (d) above, shall be placed within a close fitting
container or its contents.
fiberboard box conforming to PPP-B-640, class 2, style
(5) Marking. In addition to any special marking required
E; or PPP-B-636, type CF, class weather-resistant,
variety DW. The gross weight of boxes conforming to
by the contractual document, unit packages and shipping
PPP-B-640 shall not exceed 250 pounds.  When the
containers shall be marked in accordance with MIL-
gross weight exceeds 200 pounds, or the container
STD129.
length and width is 48 x 24 inches or more and the
b. Bill of Material. The bill of material for BA-487/U is
weight exceeds 100 pounds, containers will be pallet
mounted on pallets conforming to MIL-P-15011 or MIL-P-
given in the chart below:
3938.
Closure
TB 11-6135-200-25 shall be in
accordance with the appendix to the applicable box
specification.
Reinforcing shall be by nonmetallic
Ref
Item
No
Method
Size (in.)
Requirements
No
Nomenclature
Reqd
MIL-
P-116
L
W
D
Spec No
*T
*C
*V
*G
*F  *S
1
Battery, BA-487/U
1
111
13 ¼  11
2
Cell, Fiberboard
1
13 ¼  11
2 ½  PPP-F-320  CF  W
SW  W5c
R
3
Cell, Fiberboard
1
13 ¼  11
2 ½  PPP-F-320  CF  W
SW  W5c
R
4
Cell, Fiberboard
1
11
11 ¼  2 ½  PPP-F-320  CF  W
SW  W5c
R
5
Cell, Fiberboard
1
13 ¼  11
8 7  PPP-F-320  CF  W
SW  W5c
R
6
Box, Fiberboard
1
13 ¾  11 ¼  1 ½  PPP-B-636  CF  W
2
SW  W5c
R
*T-Type C-Class V-Variety G-Grade F-Flute S-Style