Order this information in Print

Order this information on CD-ROM

Download in PDF Format

     

Click here to make tpub.com your Home Page

Page Title: d. Temperature Circuit Resistance Check (D’Arsonval Indicator(s)).
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

Back
Figure    2-4.    D’Arsonval    Temperature    Indicator    Check    Setup.
Up
TM-55-4920-401-13P Test Set Fuel Quantity Gage Capacity Type P/N 361 010 002 Manual
Next
F i g u r e    2 - 6 .    T e m p e r a t u r e    C i r c u i t    R e s i s t a n c e    C h e c k    S e t u p

TM    55-4920-401-13&P position,   and   MASTER   POWER   switch   to   ON position. (2)  observe   reading   on   tester TEMP   indicator   and   adjust   A/C   IND   ADJ   control   to test   temperature   (usually   600   °C). (3)  The   difference   in   the   indication   of   the tester   TEMP   indicator   and   the   aircraft   indicator   is the   error   of   the   aircraft   indicator   and   should   not exceed   allowable   technical   manual   tolerance. (4)  If   aircraft   indicator   exceeds   technical manual   tolerance,   repair   or   replace   indicator. (5)  Turn   FUNCTION   SELECT   and   MASTER POWER  switches  to  OFF  position  before  removing cables   from   tester   and   aircraft. d.   Temperature   Circuit   Resistance   Check (D’Arsonval    Indicator(s)).    In   the   resistance check,   the   resistance   of   the   aircraft   thermocouple wire,    thermocouples, and   resistance   spool   is measured   on   the   tester   RESISTANCE   CHECK meter.   Refer   to   figure   2-6   and   proceed   as   follows: C A U T I O N A    h i g h    r e s i s t a n c e    c o n d i t i o n    is d a n g e r o u s     b e c a u s e     t h e     a i r c r a f t temperature   indicator   will   read   low and   the   engine   will   be   o p e r a t i n g above   indicated   temperature. (1)  Turn   FUNCTION   SELECT,   STD   DAY, and  MASTER  POWER  switches  to  OFF  position. (2)  Connect   BH485   instrument   cable   to INSTRUMENT   CABLE   receptacle   on   tester   and   to BH823   resistance   check   adapter. (3)  Disconnect   aircraft   thermocouple   leads from   indicator(s). (4)  Connect   one   set   of   aircraft   thermocouple leads   to   resistance   check   adapter   terminal   block. Make   sure   polarity   is   correct.   If   there   are   two indicators,   the   other   set   of   leads   is   left   disconnected. (5)  Turn   RESISTANCE   &   A/C   INDICATOR CHECK   switch   to   proper   resistance   position.   (See proper  aircraft  maintenance  manual  for  resistance value). (6)  Turn position   and position. FUNCTION  SELECT  switch  to  RES MASTER   POWER   switch   to   ON (7)  RESISTANCE   CHECK   meter   on   tester should   read   within   technical   manual   tolerance.   If not,  adjust  resistance  spool  in  aircraft  for  proper resistance.   One   increment   on   meter   equals   0.05 ohm. C A U T I O N Check  and  clean  all  connections  in  the t h e r m o c o u p l e     s y s t e m     b e f o r e adjusting    aircraft    resistance    spool. D e f l e c t i o n    o f    m e t e r    n e e d l e    in c l o c k w i s e    d i r e c t i o n    i n d i c a t e s excessive   resistance. (8)  If   resistance   is   within   tolerance,   proceed to   check   insulation   resistance   as   described   in paragraph   e. (9)  Turn   FUNCTION   SELECT   and   MASTER POWER  switches  to  OFF  position  before  removing cables   from   tester   and   aircraft. e .    I n s u l a t i o n    R e s i s t a n c e    C h e c k .    I n    t he insulation   resistance   check,   the   resistance   between the   thermocouple   conductors   and   aircraft   ground   is measured   first,   followed   by   a   check   of   the   resistance between   the   conductors.   Refer   to   figure   2-7   and proceed   as   follows: (1)  Turn   FUNCTION   SELECT,   STD   DAY, and  MASTER  POWER  switches  to  OFF  position. (2)  Connect   BH485   instrument   cable   to INSTRUMENT   CABLE   receptacle   on   tester   and   to BH821   insulation   check   adapter,   and   disconnect both   leads   at   aircraft   indicator. (3)  Turn   FUNCTION   SELECT   switch   to INSUL   position,   INSULATION   CHECK   switch   to RX1000   position,   an   MASTER   POWER   switch   to ON  position. (4)  Short   alligator   clips   together.   Meter should  read   0 ohms. (5)  Connect   one   lead   of   insulation   check adapter  to  a  bare  thermocouple  lead  in  aircraft  and connect   other   lead   to   aircraft   ground. (6) INSULATION  RESISTANCE  meter  should  in- dicate resistance specified for aircraft being checked. (7)  Disconnect   engine   thermocouple   harness from   airframe   thermocouple   harness. (8)  Disconnect   insulation   check   adapter   from aircraft   ground   and   connect   to   other   thermocouple lead. (9)  I N S U L A T I O N     R E S I S T A N C E     m e t er Change 4 2-7

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing