TM 1-1510-225-MTF PROCEDURE TROUBLESHOOTING REFERENCE *15. AC/DC power - Check C1-6 (a) AC frequency 380 to 420 Hz. (b) AC voltage - 105 to 120 VAC. (c)  DC  voltage  -  27.5  to  29.0  VDC. (d) DC loads: Parallel within 10%. (1)  75%  maximum  -  Low  Idle. (2)  85%  maximum  -  High  Idle. (3)   85%   maximum   -   Ground Operations. 16. AVIONICS MASTER PWR - On. 17. EFIS power switches (3) - ON. 18. Engine instruments - Check. ABORT   START 1. CONDITION lever - FUEL CUTOFF. 2.   IGNITION   AND   ENGINE   START switch - STARTER ONLY. 3. ITT - Monitor for drop in temperature. 4.   IGNITION   AND   ENGINE   START switch - OFF. ENGINE   CLEARING 1. CONDITION lever - FUEL CUTOFF. 2.   IGNITION   AND   ENGINE   START switch - OFF (1 minute minimum). 2-19