Click Here to
Order this information in Print

Click Here to
Order this information on CD-ROM

Click Here to
Download this information in PDF Format

 

Click here to make tpub.com your Home Page

Page Title: Operation
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books

   
Back
NIGHT  VISION  GOGGLES
Up
Signalman 1 & C - Aviation theories and other practices
Next
AN/PVS-11 Pocketscope

eye. Each eyepiece is adjustable through a range of +2 to -6. Each  objective  lens  assembly  is  focused  by rotating the focus knob. The objective lens is screwed into the mounting collar and the knob is attached to the lens and held in place by the focus knob retainer. Rotating  the  focus  knob  positions  the  objective  lens for viewing at desired ranges. The eye relief adjustment allows the binocular assembly to be moved within the frame for eye relief and comfort. Clamp knobs, located on either side, can be  loosened  by  turning  the  knobs  counterclockwise and manually moving the frame to reposition the binocular assembly with reference to the user's eyes. The  assembly  is  tightened  into  place  by  turning  the clamp  knob  clockwise. Operation The principles of operation are the same for the AN/PVS 5A, 5B, and 5C. The operating phase of night vision   goggles   consists   of   pre-operation,   test operation,  and  post-operation  instructions. Pre-operation   instructions: 1. Release the air pressure as instructed on the side of the storage case. 2. Release the latches and open the storage case and  remove  the  goggles.  Inspect  the  goggles  for damage. 3. Ensure the rotary switch is in the OFF position. 4. Use only one battery compartment at a time. Insert battery/batteries (AN/PVS 5A uses only one lithium battery; the AN/PVS 5B and 5C use either one lithium  battery  or  two  alkaline  batteries  in  one compartment) and replace the cap. 5. Snap the headstrap to the face mask, making sure all straps are extended to their maximum lengths. Place the head strap on your head, grasp the straps with both hands and slowly pull until the face mask cushion touches your face. Continue pulling until the goggles feel snug. Perform the same step for the vertical head strap. 6.    Remove  the  objective  and  eyepiece  lens  caps.  If demisting shields are used, snap them over the eyepiece lens. Be careful not to smudge the eyepiece lens or demisting  shield. 7.   Loosen   the   lever   clamp   and   adjust   the monoculars  for  proper  distance  between  your  eyes. Tighten  the  clamps. 8.  Loosen  the  clamp  knob  and  adjust  the  binocular assembly until the eyepieces are located a comfortable distance from your eyes with proper tilt. Tighten both clamps. Instructions for test operation: 1. Position the rotary switch to the ON position. 2. Loosen the lever clamp and adjust the goggles for proper spacing between the monocular eyepieces. Retighten  the  clamp. 3. Loosen both clamp knobs and adjust the goggles for proper tilt and eye relief. Retighten the clamp knobs. 4. On the AN/PVS 5A and 5B, turn the focus knob fully counterclockwise on each objective lens for distant viewing. Adjust for the clearest view. The focus knob may be turned fully clockwise to adjust for a minimum focus of 10 inches. On the AN/PVS 5C goggles, the focus function is part of the objective lens assembly. To focus the goggles for the sharpest view, grasp the outside of each objective lens assembly and turn it to obtain the sharpest image. 5. Adjust each diopter ring until the image is sharp (the  diopter  ring  adjusts  the  diopter  for  each  individual user and does not require movement after initially set). 6. Pull and turn the rotary switch for IR operation (optional test). Return the switch to ON for normal operation. The rotary switch turns the goggles and IR illuminator on and off. Be sure it is turned to OFF when the goggles are not in use. Post-operation   instruction: 1. Remove the demisting shields, if installed, by grasping them and pulling them off the eyepiece lenses. Return  them  to  their  case. 2. Replace the objective and the eyepiece lens cap. 3. Ensure the rotary switch is in its OFF position. Remove the battery (or batteries) from the battery compartment(s) and return it to its case. Replace the battery caps. 4. Inspect the face mask cushion for tears, cracks, or missing snaps; also inspect the goggles for missing parts. 5. Clean the goggles, carrying case, and shipping case as necessary with fresh water. Ensure both cases and liner are dry prior to storing the goggles in them. 2-18

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing