PREFLIGHT/POSTFLIGHT INSPECTION
Up
Aircrew Survival Equipmentman 2 - Aviation theories and other practices
Next
CHAPTER 5 RESCUE AND SURVIVAL EQUIPMENT

CAUTION ENSURE   THAT   CLEANING   SOLU- TION   DOES   NOT   ENTER   THE   IN- HALATION/EXHALATION    VALVE ASSEMBLY. Moisten a gauze pad with the cleaning solution and wash the facepiece and housing assembly both internally and externally. After washing, the mask should be thoroughly and  repeatedly  rinsed  with  warm  water. NOTE:   Another   alternate   sanitizer, Aerosol  Antiseptic  Spray  SBT-12  (di- bromosalicyl  bromanicide),  manufactured by Lever Brothers, Inc., can be used. Directions for use are indicated on the container. After  all  parts  are  dry,  disinfect  by  using  a gauze  pad  or  other  lint-free  wipers,  with  a  solution of  2  tablespoons  of  chlorine  bleach  per  gallon  of water;  rinse  with  clear  water  and  air  dry.  Be certain disinfectant reaches inner crevices of the faceform. To  clean  the  delivery  hose,  wash  it  with  a cleaning  solution  and  rinse  it  with  clear  water. Allow  all  parts  to  air  dry. When  cleaning  the  inhalation/exhalation  valve assembly,  it  will  be  necessary  for  you  to  obtain a container just large enough to partially submerge the  valve.  Fill  the  container  half  full  of benzalkonium chloride solution, MIL-B-37451, or a solution of 70 percent isopropyl alcohol and 30 percent distilled water. 239.423 Figure  4-27.—Removing  locking  nut. By using a valve wrench, as shown in figure 4-27,   unscrew   the   valve   nut   and   remove   the locking nut, bearing washer, and isolation washer from the inside of the mask. This will allow the valve,   sealing   washer,   delivery   tube,   and connector assembly to be removed as a unit from the  outside  of  the  mask.  Hold  the  base  portion of the valve and submerge the operating portion of  the  valve  into  the  solution.  Normally,  only  a few seconds are required to remove any stains and residue. For stubborn residues, use a cotton swab saturated  with  benzalkonium  chloride  and  rub lightly  to  remove.  Gently  shake  excess  solution from  oxygen  valve  and  allow  it  to  air  dry completely. 4-32