Click Here to
Order this information in Print

Click Here to
Order this information on CD-ROM

Click Here to
Download this information in PDF Format

 

Click here to make tpub.com your Home Page

Page Title: REGULATED LOW-PRESSURE NITROGEN SYSTEM
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books

   
Back
PRESSURIZING THE REGULATED HIGH-PRESSURE SYSTEM
Up
Aircrew Survival Equipmentman 1 & C - Aviation theories and other practices
Next
PRESSURIZING THE ROTAMETER SYSTEMS

A   pressure   drop   on   the   regulated   low-pressure gage   indicates   that   the   leakage   on/off   valve   is leaking.   This   completes   your   leakage   check.   You must   bleed   the   system   by   turning   the   high-pressure regulator   to   the   VENT   position   until   the   high- -pressure  gage  reads  zero  and  then  open  the  system bleed  valve.  This  bleeds  all  remaining  lines. REGULATED    LOW-PRESSURE NITROGEN   SYSTEM The   purpose   of   the   regulated   low-pressure nitrogen   system   is   to   supply   regulated   low- pressure   nitrogen   to   the   N2 input   connection   and the   in-system   leakage   rotameters.   This   system, shown  in  figure  2-5,  has  a  range  of  0  to  180  psig. You   adjust   the   pressure   by   using   the   mechanically operated   low-pressure   regulator.   When   you   open the   low-pressure   regulator,   nitrogen   flows   through the   one-way   check   valve   to   the   back   side   of   the one-way   check   valve   that   protects   the   high- -pressure   regulator. A s    n i t r o g e n    e n t e r s    t he high-pressure   lines,   it   flows   to   the   inlet   pressure on/off  valve,  the  system’s  bleed  valve,  the  vent pressure   valve,   and   through   the   gage   guard   that protects   the   in-systems   leakage   rotameters. (Nitrogen   also   flows   into   the   rotameters   and   to the   200-   to   230-psig   relief   valve.   However,   this is  not  considered  part  of  the  low-pressure  system. For   the   nitrogen   to   flow   to   the   item   under   test, you  have  to  open  the  inlet  pressure  on/off  valve. T h i s    a l l o w s    n i t r o g e n    t o    f l o w    t o    t h e    i n p ut connection   inside   the   chamber   where   the   item under   test   is   connected. PRESSURIZING   THE   REGULATED LOW-PRESSURE   NITROGEN   SYSTEM When   you   pressurize   the   low-pressure   nitrogen system,  be  sure  that  the  N2 input   connection   is capped  and  the  supply  cylinder  valve  is  open.  Turn the   leakage   selector   valve   to   the   HIGH   position and   the   pressure   selector   valve   to   the   HG position.   Turn   the   inlet   pressure   and   leakage on/off  valves  to  the  ON  position.  Slowly  turn  the l o w - p r e s s u r e    r e g u l a t o r    c l o c k w i s e    u n t i l    t he regulated  low-pressure  gage  and  the  N2 input   gage indicate  70  psig.  (We  use  70  psig  because  this  is the   pressure   used   to   calibrate   the   rotameter system.)   At   this   time,   return   the   inlet   pressure on/off   valve   to   OFF.   There   should   be   no   leakage; but  if  any  leakage  occurs,  the  small  ball  in  the high-range   leakage   rotameter   tube   will   rise. Figure 2-5.—Model 1172AS100 regulated low pressure N2 system. 2-6

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing