Page Title: Figure 1-4.—Flowmeter Calibration Kit
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books

   
Back
Differential Pressure Gage (DF-1)
Up
Aircrew Survival Equipmentman 1 & C - Aviation theories and other practices
Next
TROUBLESHOOTING

Close   system   bleed   valve   V-5,   and   open   test pressure   gage   to   bell   jar   valve   V-2. 2.  Open  oxygen  supply  valve  V-6  until  160 psig    registers    on    the    precision-0-to-200-psig pressure   gage;   then   close   valve   V-6. 3 .    C o m p a r e    t h e    p r e c i s i o n - 0 - t o - 2 0 0 - p s ig pressure   gage   reading   with   pressure   registered   on test   pressure   gage   PG-1.   Enter   the   corrective differential   (if   any)   in   the   indicated   psig   column of   test   stand   correction   card   number   2. 4.   Slowly   open   system   bleed   valve   V-5   to r e d u c e    t h e    p r e s s u r e    r e g i s t e r e d    o n    t h e precision-0-to-200-psig   pressure   gage.   Enter   the corrective   differential   (if   any)   at   each   specified pressure   on   the   test   stand   correction   card. 5.   After   all   correction   card   entries   have   been completed,   close   system   bleed   valve   V-5   and oxygen   supply   valve   V-6. Low-Pressure   Test   Gage   (PG-4) To   prepare   a   low-pressure   test   gage   (PG-4) correction   card,   proceed   as   follows: 1.   With   precision-0-to-200-psig   test   gage   4 (figure   1-3)   still   attached   to   bell   jar   bottom coupling   C-1,   open   oxygen   supply   valve   V-6 until   7.5   psig   is   indicated   on   the   precision-0- to-200-psig  test  gage.  The  pointer  of  low-pressure test   gage   PG-4   should   be   at   midscale.   If   the pointer   is   not   at   midscale,   adjust   by   turning   the adjustment   screw   on   the   back   of   the   gage. 2.   Slowly   open   oxygen   supply   valve   V-6 until   14   psig   registers   on   the   precision-0-to-200- psig  test  gage;  then  close  oxygen  supply  valve  V-6. Compare   the   reading   with   the   indication   on low-pressure   test   gage   PG-4.   Enter   the   corrective differential   (if   any)   in   the   indicated   psig   column of   test   stand   correction   card   number   3. 3.  Slowly  open  system  bleed  valve  V-5  and r e d u c e    t h e    p r e s s u r e    i n d i c a t e d    o n    t h e precision-0-to-200-psig   pressure   test   gage   in   2-psig increments.   At   each   increment,   enter   the   correc- tive   differential   (if   any)   on   the   test   stand   correc- tion   card. 4.   After   all   correction   card   entries   have   been completed,   ensure   oxygen   supply   valve   V-6   is closed;  then  open  system  bleed  valve  V-5  and  close test-pressure-gage-to-bell-jar   valve   V-2.   Remove the  precision-0-to-200-psig  test  gage  from  bell  jar base   coupling   C-1. . Linear   Flow   Elements   (FLM-4), (FLM-3),   (FLM-2),   and   (FLM-1) To   prepare   the   linear   flow   element   correction cards,  place  the  Flowmeter  Calibration  Kit  (shown in  figure  1-4)  on  the  test  stand  counter  top;  then Figure 1-4.—Flowmeter Calibration Kit. 1-7