CORRECTION CARD PREPARATION AND CALIBRATION
Up
Aircrew Survival Equipmentman 1 & C - Aviation theories and other practices
Next
Figure 1-4.—Flowmeter Calibration Kit

4.   Using   applicable   graphs,   repeat   steps   1 through  3  for  all  actual  flows  given  on  correction cards   4   through   7. 5.   Indicated   flows   (in.   H2O)   are   entered   on the   cards   when   you   calibrate   the   test   stand. Differential   Pressure   Gage   (DF-1) To    prepare    the    differential    pressure    gage (DF-1)   correction   card,   refer   to   figure   1-1   in   the following   steps: 1.   Close   system   bleed   valve   V-5   and   open   the o x y g e n    s u p p l y    c y l i n d e r    v a l v e .    C o n n e ct precision-0-to-100-in.   H2O   low-pressure   gage   6 (figure   1-3)   to   bell   jar   bottom   coupling   C-1.   Open differential   pressure   shutoff   valve   V-8. NOTE:   Correction   cards   will   be   completed   at this   time. 2.   Slowly   open   oxygen   supply   valve   V-6 u n t i l    1 0 0    i n .    H2 O    i s    i n d i c a t e d    o n    t h e precision-0-to-100-in.    H2O    low-pressure    gage. Compare   this   gage   with   the   reading   displayed   on differential   pressure   gage   DF-1. 3.   Enter   the   difference   (if   any)   in   the   indicated in.   H2O   column   of   correction   card   number   1. 4.   Slowly   open   system   bleed   valve   V-5   to r e d u c e     t h e     p r e s s u r e     i n d i c a t i o n     o n     t he precision-0-to-100-in.     H2O   low-pressure   gage. Reduce   pressure   in   20-in.   H2O   increments.   Enter the   corrective   differential   (if   any)   at   each   interval on   the   correction   card. 5.   When   all   entries   have   been   made   on   the correction   card,   close   oxygen   supply   valve   V-6   and differential   pressure   shutoff   valve   V-8. 6.   Open   system   bleed   valve   V-5   and   bleed   the system.   Disconnect   the   precision-0-to-100-in.   H2O low-pressure    gage. Test   Pressure   Gage   (PG-1) To   prepare   the   test   pressure   gage   (PG-1)   cor- rection   card,   proceed   as   follows: 1.    Connect    precision-0-to-200-psig    pressure gage  4  (figure  1-3)  to  bell  jar  bottom  coupling  C-1. Figure 1-3.—Pressure Gage Calibration Kit. 1-6