Page Title: CORRECTION CARD PREPARATION AND CALIBRATION
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books

   
Back
Cleaning
Up
Aircrew Survival Equipmentman 1 & C - Aviation theories and other practices
Next
Differential Pressure Gage (DF-1)

W A R N I NG Never   apply   oil,   grease,   or   any   other material   not   approved   for   use   in   the presence   of   gaseous   and   liquid   oxygen systems. CORRECTION   CARD   PREPARATION AND    CALIBRATION An   on-site   CAL   TEAM   must   prepare   the c o r r e c t i o n    c a r d s    a n d    c a l i b r a t e    t h e    5 9 A 1 20 f o l l o w i n g    N A V A I R    1 3 - 1 - 6 . 4    p r o c e d u r e s. H o w e v e r ,    b e c a u s e    o f    t h e    o p e r a t i o n a l    c o m- mitments   of   today’s   Navy,   you   may   find   yourself with   a   test   stand   that   needs   calibration   and correction   card   corrections   when   CAL   TEAM services   are   not   available.   This   chapter   covers t h e    p r o c e d u r e s    o u t l i n e d    i n    t h e    N A V A I R 17-15BC-20   for   correction   card   preparation   and calibration. NOTE:   This   RTM  does  not  authorize   you   to calibrate   the   test   stand   nor   does   it   authorize   you to   make   correction   card   corrections.   These   tasks CORRECTION   CARDS Before   you   operate   the   59A120   test   stand, individual   correction   cards   for   the   following components   must   be   prepared:   DF-1,   PG-1, PG-4,   FLM-1,   FLM-2,   FLM-3,   and   FLM-4. These   correction   cards   must   be   prepared   prior   to calibration   of   the   59A120   test   stand. To   perform   calibration   and   to   prepare   correction cards,   you   will   need   the   Flowmeter   Calibration Kit   and   the   four   graphs   that   are   supplied   with   the kit   for   that   particular   test   stand.   Each   kit   will   be serialized   with   the   same   number   as   the   serial number   of   the   test   stand. To   prepare   the   cards,   convert   the   actual l i t e r - p e r - m i n u t e     ( l p m )     f l o w s     t o     i n d i c a t ed millimeter   (mm)   flows   on   cards   4,   5,   6,   and   7. Refer   to   figure   1-2   in   the   following   steps: 1 .    U s i n g    t h e    a p p l i c a b l e    g r a p h    f o r    t he flowmeter   selected,   locate   the   desired   lpm   at   the bottom   of   the   graph. 2.   Trace   the   selected   lpm   lineup   to   where   it intersects   the   graph   line. 3.   Trace   the   line   from   point   of   intersection to   the   left-hand   edge   of   the   graph   to   determine mm.   Enter   this   figure   in   the   appropriate   column must   be   authorized   by   higher   authority. of   the   correction   card. Figure 1-2.—Conversion Example. 1-5