MD regulator operational drawing
Up
Aviation Structural Mechanic E2 - How airplanes are built and how to maintain them
Next
Troubleshooting (Daily, preflight, special, turnaround, transfer and acceptance inspections)

diaphragm  (6)  forces  the  demand  valve  lever assembly  (7)  down.  The  pressure  differential exists during the inhalation cycle of the user by creating a reduction in the pressure outlet (8). 4.  Reduction  in  pressure  at  the  pressure outlet is sensed in the demand diaphragm chamber (9) through the sensing port (10). 5 During periods of flow, the oxygen passes through the venturi assembly (11). At the venturi assembly, the flow of oxygen mixes with ambient air, which enters the regulator through the inlet ports (12). 6. The addition of ambient air to oxygen is controlled by the manual diluter control lever (13) and by the diluter aneroid assembly (14), which automatically  produces  a  100-percent  oxygen concentration at altitudes above 32,000 feet. 7. The aneroid check valve assembly (15) prevents a flow of oxygen out through the inlet ports. 8. The emergency pressure control lever (16) applies force to the emergency pressure control test  spring  (17),  which  mechanically  loads  the emergency pressure diaphragm (25) through the control lever and center assembly (18). Mechanical loading  of  the  emergency  pressure  diaphragm provides  positive  pressure  at  the  regulator  outlet. 9.  Both  automatic  safety  pressure  and pressure  breathing  at  altitudes  above  30,000  feet are  provided  through  pneumatic  actuation  of  the aneroid assembly (19). This function begins near 27,000  feet  altitude.  The  force  exerted  on  the diaphragm assembly (20) by the aneroid assembly actuates the pressure breather valve assembly (21), and oxygen flows to the diaphragm and the plate assembly (22), which is pressure loaded by this volume of oxygen acting on the demand valve lever  assembly  to  the  extent  that  the  positive pressure is built up at the pressure outlet as the altitude  increases. 10.  Additional  safety  is  obtained  through  the inclusion of the second-stage relief valve assembly (23) in the regulator. TURNAROUND/PREFLIGHT/POST- FLIGHT/TRANSFER  INSPECTIONS.—  These inspections are visual inspections performed in conjunction  with  the  inspection  requirements  for the aircraft in which the regulators are installed. Refer  to  table  4-3  for  assistance  in  trouble- shooting. Visually  inspect  the  following: 1. Electrical performance of the panel light 2. Legibility of all the markings 4-20 3. 4. 5. 6. 7. 8. 9. Plastic  lighting  plate  for  cracks  and discoloration Low  or  improper  reading  on  regulator pressure  gauge Emergency   pressure   control   lever   in NORMAL  position Diluter control lever in 100% OXYGEN position Supply valve control lever in OFF position Regulator and surrounding area free of dirt and  hydrocarbons Delivery  hose  and  connector  for  cuts, fraying,  kinking,  hydrocarbons,  and general condition If   discrepancies   are   found   or   suspected. maintenance   control   should   be   notified. Regulators  that  do  not  pass  inspection  and cannot be repaired in the aircraft are removed and replaced by ready-for-issue (RFI) regulators.  Non- RFI  regulators  are  forwarded  to  the  nearest maintenance activity having repair capability. ACCEPTANCE/SPECIAL/DAILY    IN- SPECTIONS.—  These  inspections  are  visual inspections followed by a functional test. These inspections and tests are performed in conjunc- tion  with  the  inspection  requirements  for  the  air- craft in which the regulators are installed. Refer to table 4-3 for assistance in troubleshooting. WARNING Make certain that when working with oxygen,  all  clothing,  tube  fittings,  and equipment  are  free  of  oil,  grease,  fuel, hydraulic fluid, or any combustible liquid. Fire  and/or  explosion  may  result  when even  slight  traces  of  combustible  material come   in   contact   with   oxygen   under pressure. To  perform  the  functional  test,  proceed  as follows: 1. Place supply valve control lever in the ON position. 2.  Place  the  diluter  control  lever  in  the NORMAL OXYGEN position. 3.  Connect  the  oxygen  hose  to  the  quick disconnect,  place  the  mask  to  the  face,  and inhale.   Proper   regulator   operation   will   be indicated  by  the  flow  indicator  assembly