Click Here to
Order this information in Print

Click Here to
Order this information on CD-ROM

Click Here to
Download this information in PDF Format

 

Click here to make tpub.com your Home Page

Page Title: Operation
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books

   
Back
LEADING  EDGE  TEMPERATURE  AND OVERHEAT   CIRCUIT
Up
Aviation Structural Mechanic E1&C - How airplanes are built and how to maintain them
Next
RAIN  REMOVAL  SYSTEM

sensing   element.   The   switches   sense   still   air temperature. The outboard leading edge overheat warning  switches  open  at  approximately  205°F and  close  at  approximately  220°F.  The  other  wing and fuselage overheat warning switches open at approximately 175°F and close at approximately 190°F. High temperature within the leading edge is generally  caused  by  bleed-air  leakage  or malfunctioning modulator valves. You can detect the  portion  of  the  leading  edge  that  has  the overtemperature  by  placing  the  rotary  selector switch,  located  on  the  ice  control  protection  panel, to the different sensor positions: INBD, CTR, and OUTBD.  (See  fig.  3-4.)  The  temperature  at  the selected  sensor  is  then  read  at  the  indicator adjacent   to   the   rotary   switch.   An   excessive temperature  reading  on  the  indicator  denotes  a malfunction  within  the  area  being  tested. Operation Figure  3-4,  the  ice  control  protection  panel, shows a basic diagram of the wing deice system. Each  engine  is  labeled  by  an  engine  number. Directly below each engine block (in the diagram) is an OPEN light that illuminates when the bleed- air  valve  is  open  2  degrees  or  more.  The  cross- ship  manifold  from  the  bleed-air  valves  goes  to each  modulating  valve  and  the  fuselage  shutoff valves. The fuselage bleed-air shutoff valves are normally  in  the  CLOSE  position  during  normal deicing  operation.  The  bleed-air  pressure  gauge reads  cross-ship  manifold  pressure  when  one  or both  switches  are  opened. A  ground  air-conditioning  switch  is  located directly  under  the  bleed-air  manifold  pressure gauge. Located above the switch is an annunciator light,  which  indicates  VALVE  OPEN  when  the ground air-conditioning valve is open. Either one or both fuselage bleed-air shutoff valves must be open to direct air to the ground air-conditioning unit. A  leak  test  switch  is  mounted  on  the  upper right-hand side of the panel. This switch is used to  determine  if  the  leakage  of  the  system  is acceptable. Three  modulating  valve  control  switches  are located on the left side of the wing and empennage ice  panel.  The  outboard  switch  controls  the outboard modulating valve on the left and right wing,  the  center  switch  controls  the  two  center modulating  valves,    and   the   inboard   switch controls  the  two  inboard  modulating  valves. During   normal   operation   of   the   deicing system, all four engine bleed-air valves are open to  supply  bleed  air  to  the  cross-ship  manifold,  and both fuselage bleed-air shutoff valves are closed. Figure 3-4.-Ice control protection panel. 3-5

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing