Click here to make tpub.com your Home Page

Page Title: REG-FILT. SHUT-OFF 50-6518 OPERATING & MAINTENANCE INSTRUCTIONS
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Back
TROUBLESHOOTING AND REPAIR
Up
TM-9-4940-428-14-P Spray Outfit Paint Model 50-6519 (Eclipse Systems Inc) (4940-00-857-2290) Manual
Next
PARTS LIST, `76 GUN 50-6510

REG-FILT. SHUT-OFF
50-6518
OPERATING
&
MAINTENANCE INSTRUCTIONS
Supply air inlet is a 1/2" NPT on the side of filter head (1).
The shut-off valve (7) on the side of filter (1) is filtered supply line
pressure air.
Regulated filtered air is supplied thru the regulator (4) mounted
on the side of filter (1). The regulator (4) is used to control the air
pressure. Turn the adjustment rod on the regulator (4) out to
decrease air pressure and in to increase air pressure. When
desired air pressure is maintained, tighten locknut on the
adjustment rod. Regulated filtered air is supplied to the shut-off
valves (7) mounted on the side of the regulator (4). Regulated
filtered air pressure is indicated on a pressure gauge (6)
mounted on the regulator head.
Gauge reads in pounds per square inch (PSI) from 0-160 PSI.
The bowl of the filter (1) should be drained daily or whenever
water accumulates in the bottom of the bowl. To drain, open the
drain valve on the bottom of the valve.  The filter should be
disassembled and cleaned periodically.
DISASSEMBLY OF FILTER FOR CLEANING AND
MAINTENANCE.
CAUTION
Turn off the air supply before loosening or
removing any parts from this unit.
FILTER DISASSEMBLY
Remove bowl and bowl guard by pressing lever and turning ring
and remove parts by sliding off. Unscrew baffle to remove filter
element. Clean element by tapping on hard surface and blowing
off with air blow gun. To assemble follow above instructions in
reverse.
REGULATOR MAINTENANCE
Occasionally unscrew plug and clean internal parts. Gauges (6),
valves (7), mounting bracket (5) and fittings may be removed for
cleaning or replacing by unscrewing from filter (1) or regulator (4).
3

Privacy Statement - Press Release - Copyright Information. - Contact Us