FAULTY PATTERNS and how to correct them
Up
TM-9-4940-348-14-P Spray Outfit Pressure Tank Model 98-305 National Stock No. 4940-00-650-7819 Manual
Next
MODEL 31-116 AIR MOTOR DRIVE UNIT INSTRUCTIONS

MODEL 18 SPRAY GUN
GENERAL MAINTENANCE
SPRAY GUN
PRECAUTIONARY NOTE
1.
Immerse only the front end of the gun until
All parts on a spray gun should be screwed in hand
solvent just covers the fluid connection.
tight at first; this will avoid the possibility of cross
2.
Use a bristle brush and solvent to wash off
threading the parts. If the parts can not be turned by
accumulated paint.
hand easily, make sure you have the correct parts,
3.
Do not submerge the entire spray gun in solvent
unscrew, realign, and try again. NEVER use undue
because
force in mating parts.
a.  the lubricant in the leather packings will
dissolve and the packings will dry out.
AIR NOZZLE, FLUID NOZZLE, NEEDLE ASSEMBLY
b.  the lubricant at wear surfaces will dissolve
1.
All nozzles and needles are precision made.
causing harder operation and faster wear.
They should be handled with care.
c.  residue from dirty solvent may clog the
2.
Except as described in 5., do not make any
narrow air passages in the gun.
alterations in the gun.  To do so could cause
4.
wipe down the outside of the gun with solvent
finishing difficulties.
dampened rag.
3.
To clean nozzles, soak them in solvent to
5.
Lubricate gun daily. Use a light machine oil on.
dissolve any dried material, then blow them
a.  fluid needle packing.
clean with air.
b.  air valve packing.
4.
Do not probe any of the holes m the nozzles with
c.  side port control packing.
metal instruments. If probing is necessary, use
d.  trigger pivot point.
only a tool that Is softer than brass.
Coat the fluid control spring with vaseline.
5.
Adjust the fluid needle valve so that when gun is
6.
Caution:  Never use lubricants containing
triggered, air-flow occurs before fluid-flow.
silicone.
This material may cause finish defects.
POINTERS ON CLEANING
WHEN USED WITH SIPHON CUP
A compatible thinner or solvent should be siphoned
through gun by inserting tube m open container of that
liquid. Trigger gun repeatedly to flush passageway
thoroughly and to clean tip of needle.
WHEN USED WITH PRESSURE TANK
Shut off air supply to tank and release pressure on tank.
Open vent and loosen air nozzle. Hold a piece of cloth
over the air nozzle and squeeze trigger. Air will back up
through fluid nozzle, and force fluid out of hose into tank.
Next, put enough thinner into tank to wash hose and gun
thoroughly.  Spray thinner through the gun until it is
clean.  Attach fluid hose to air line and blow it out
thoroughly to remove all traces of materials and to dry it.