TROUBLESHOOTING (Continued)
Up
TM-9-4910-663-34 Heater Immersion Liquid Fuel Fired 36 000 BTU Output for Corrugated Cans Manual
Next
TROUBLESHOOTING (Continued)

TM- 9-4910-663-34 Table 2-5.  TROUBLESHOOTING (Continued) MALFUNCTION TEST OR INSPECTION CORRECTIVE ACTION If  open  circuit  indication  is  obtained,  proceed  to  step  10;  if  normal  indication  is  obtained,  proceed directly to step 12. Step  10.  Using  ohmmeter,  check  for  1.14  ohm  ±5%  indication  between  REGULATOR  B-binding  post  and- terminal 20 of load bank. If open circuit indication is obtained, replace load bank element. Step 11.  Using ohmmeter, check for continuity across terminals of LOAD SELECTION 25 AMPS/12.5 AMPS switch S23 with switch set to ON position. Replace switch S23 if open indication is obtained. Step  12.    Set  LOAD  SELECTION  25  AMPS/12.5  AMPS  switch  S23  to  OFF  position.    Set  DC  AMMETER LOAD  &  STARTER  OUTPUT  CURRENT  BATTERY  CHARGE  CURRENT  RANGE  switch  S14  to LOAD X3 position.  Set LOAD SELECTION 50 AMPS/25 AMPS switch S22 to ON position.  With circuit   breaker   switch   CB1   set   to   ON   position,   check   for   0.57   ohm   ±5%   indication   between REGULATOR B±  and REGULATOR B-bending posts, using ohmmeter. If  resistance  indication  is  not  as  specified,  proceed  to  step  13;  if  resistance  indication  is  normal, proceed to step 18. Step 13.  Set LOAD SELECTION 50 AMPS/25 AMPS switch S22 to OFF position.  Using ohmmeter, check for 1.14 ohm ±5% indication between REGULATOR B-binding post and each of terminals 17 and 18 of load bank. If either resistance indication is not as specified, replace load bank element. Step  14.    Using  ohmmeter,  check  for  continuity  across  each  set  of  contacts  of  LOAD  SELECTION  50 AMPS/25 AMPS switch S22 with switch set to ON position. Replace switch S22 if open indication is obtained for either or both sets of contacts. 2-28

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing