TROUBLESHOOTING (Continued)
Up
TM-9-4910-663-34 Heater Immersion Liquid Fuel Fired 36 000 BTU Output for Corrugated Cans Manual
Next
TROUBLESHOOTING (Continued)

TM- 9-4910-663-34 Table 2-5.  TROUBLESHOOTING (Continued) MALFUNCTION TEST OR INSPECTION CORRECTIVE ACTION 4.  RELAY CONTACT CLOSURE CIRCUIT/DC CONTROL POWER a.    WITH  JUMPER  CONNECTED  BETWEEN  RELAY  CONTACTS  INPUT  BINDING  POSTS,  CONTACT  CLOSURE INDICATOR DS7 FAILS TO LIGHT. Step 1.  Check to make sure that circuit breaker switch CB1, CIRCUIT BREAKERS CB2 DRIVE CONTROL circuit breaker, and CIRCUIT BREAKERS CB5 RELAY CONTROL circuit breaker are all set to ON position. Set circuit breakers to ON position. Step 2.  Set circuit breaker switch CB1 to OFF position.  Remove lamp from CONTACT CLOSURE indicator DS7, and check lamp filament for continuity with ohmmeter. Replace lamp if open indication is obtained. Step 3.  With circuit breaker switch CB1 set to OFF position, check resistance across terminals of resistor R5 with ohmmeter. Replace resistor RS if resistance indication is not within 150 ±15 ohms. Step  4.    Set  circuit  breaker  switch  CB1  to  ON  position.    Using  DC  voltmeter,  check  for  26  to  30  volt  DC indication between RELAY CONTACTS INPUT binding posts. If DC voltage is not as specified, set circuit breaker switch CB1 to OFF position and proceed to step 5. Step 5.  With circuit breaker switch CB1 set to OFF position, disconnect lead from one terminal of CIRCUIT BREAKERS  CB5  RELAY  CONTROL  circuit  breaker.    Using  ohmmeter,  check  for  continuity  across terminals of circuit breaker CB5 with circuit breaker set to ON position. Replace circuit breaker CB5 if open indication is obtained. Step 6.  Reconnect lead disconnected in step 5.  Disconnect lead from ±  terminal of rectifier assembly CR1 2-23

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing