TROUBLESHOOTING (Continued)
Up
TM-9-4910-663-34 Heater Immersion Liquid Fuel Fired 36 000 BTU Output for Corrugated Cans Manual
Next
TROUBLESHOOTING (Continued)

TM- 9-4910-663-34 Table 2-5.  TROUBLESHOOTING (Continued) MALFUNCTION TEST OR INSPECTION CORRECTIVE ACTION Replace circuit breaker CB3 or CB4 if open indication is obtained. Step  5.    Reconnect  leads  disconnected  in  step  4.    Set  circuit  breaker  switch  CB1  to  ON  position.    Open rectifier chamber door and visually examine wheel of blower B2 while pressing START switch S3. Replace blower motor B2 if wheel fails to rotate. 2.  REGULATOR FIXED RESISTANCE CIRCUIT a.  REGULATOR TESTS INVOLVING USE OF FIXED RESISTANCES PRODUCE ABNORMAL RESULTS, EVEN WITH REGULATOR KNOWN TO BE GOOD. Step 1.  Check to see that REGULATOR CHECK FIXED RESISTANCE METHOD switch S13 is set to ON position. Set switch S13 to ON position. Step    2.        Using    ohmmeter,    check    for    continuity    across    terminals    of    REGULATOR    CHECK    FIXED RESISTANCE METHOD switch S13 with switch S13 set to ON position. Replace switch S13 if open indication is obtained. Step  3.    Using  ohmmeter,  check  for  7  ohm  ±10%  indication  between  REGULATOR  B-binding  post  and REGULATOR CHECK FIXED RESISTANCE METHOD 7 OHM binding post. Replace resistor R13 if resistance indication is not as specified. Step 4.  Using ohmmeter, check for 2-1/4 ohm ±10% indication between REGULATOR B-binding post and REGULATOR CHECK RIXED RESISTANCE METHOD 2 1/4 OHM binding post. Replace resistor R12 if resistance indication is not as specified. Step 5.  Using ohmmeter, check for 1-1/2 ohm ±10% indication between REGULATOR B-binding post and REGULATOR CHECK FIXED RESISTANCE METHOD 1 1/2 OHM binding post. Replace resistor R11 if resistance is not as specified. 2-20

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing