![]() ![]() TB 9-2350-368-25
h. Starter Cable (M113A2/M548A1)
Bill Of Materials
Item
Nomenclature
Part Number
NSN
Qty
1
Receptacle Connector
7715781
1
2
Nonmetallic Bushing
8376776
5365-00-318-8184
1
3
Bushing Retainer Nut
7723308
5935-00-333-9414
1
4
Lug Terminal
MS20659-135
5940-00-115-5001
1
5
Electrical Wire
M13486/1-14
6145-00-705-6674
A/R
6
Band Marker
M43436/1-1
9905-00-752-4649
2
1. Measure from the M113A2 engine harness to power bus bar.
2. Connect AWG 1/0 electrical lead (5) measured in step 1, to receptacle connector (1-3).
3. Label leads (5), using band markers (6) as circuit 6.
4. Install lug terminal (4) on lead (5). See Figure 2-25.
|
|