Click here to make tpub.com your Home Page

Page Title: Starter Cable (M113A2/M548A1)
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Back
Starter Cable (M113A3/M548A3)
Up
TB-9-2350-368-25 Fabrication and Operation of Powerplant Test Stand Manual
Next
SECTION VI. INSTRUMENT PANEL

TB 9-2350-368-25
h. Starter Cable (M113A2/M548A1)
Bill Of Materials
Item
Nomenclature
Part Number
NSN
Qty
1
Receptacle Connector
7715781
1
2
Nonmetallic Bushing
8376776
5365-00-318-8184
1
3
Bushing Retainer Nut
7723308
5935-00-333-9414
1
4
Lug Terminal
MS20659-135
5940-00-115-5001
1
5
Electrical Wire
M13486/1-14
6145-00-705-6674
A/R
6
Band Marker
M43436/1-1
9905-00-752-4649
2
1. Measure from the M113A2 engine harness to power bus bar.
2. Connect AWG 1/0 electrical lead (5) measured in step 1, to receptacle connector (1-3).
3. Label leads (5), using band markers (6) as circuit 6.
4. Install lug terminal (4) on lead (5). See Figure 2-25.
Figure 2-25. Starter Cable (M113A2/M548A1)

Privacy Statement - Press Release - Copyright Information. - Contact Us