Transmission Cable
Up
TB-9-2350-368-25 Fabrication and Operation of Powerplant Test Stand Manual
Next
Starter Cable (M113A2/M548A1)

TB 9-2350-368-25
g. Starter Cable (M113A3/M548A3)
Bill Of Materials
Item
Nomenclature
Part Number
NSN
Qty
1
Electrical Plug Connector
MS3456W32-1P
5935-01-181-8997
1
2
Lug Terminal
MS20659-135
5940-00-155-5001
2
3
Electrical Wire
M13486/1-14
6145-00-705-6674
A/R
4
Electrical Insulation Tape
07099 - MS70T09-S
5970-00-955-9976
A/R
Electrical Insulation Sleeving
78286-S6132-
5970-00-004-4056
A/R
61003-9
5
Band Marker
M43436/1-1
9905-00-752-4649
4
1. Measure from the M113A3 engine harness to power bus bar.
2. Connect two AWG 1/0 electrical leads (3) measured in step 1, to electrical plug connector (1).
3. Label leads (3), using band markers (5), from pin E, 6; and pin B, 6A.
4. Install lug terminal (2) on each lead (3).
5. Install electrical insulation tape/sleeving (4) on both leads (3). See Figure 2-24.
Figure 2-24. Starter Cable (M113A3/M548A3)