Figure 2-20. Accessory Cable (M113A2/M113A3/M548A1 Only)

TB 9-2350-368-25
4. Measure from the M113A3 engine cable to instrument panel/box components.
5. Connect seven AWG 14 electrical leads (4), two or three inches longer than measurement in step 4, to
receptacle (1).
6. Label leads (4) from pin B, 1B (14); pin C, 406 (11); pin D, 34 (10); pin E, 33 (14); pin F, 1C (16); pin G,
327 (10); and pin H, 74 (15).
7. Splice six leads from M113A2 receptacle (7) to six common leads from M113A3 receptacle (1).
8. Install electrical insulation tape/sleeving (5) on all leads except 2 circuit leads 1B.
9. Add terminals and connectors to ends of circuit leads.
NOTE
Steps 10 through 14 are only for fabricating an adapter to connect
the M113A3 accessory cable to the M548A3 powerplant.
10. Cut six AWG 14 electrical leads 18 inches long.
11. Connect six AWG 14 electrical leads to pins C, D, E, F, G, and H of connectors, bushings, and nuts.
12. Label leads from pin C, 406; pin D, 34; pin E, 33; pin F, 1C; pin G, 327; and pin H, 74.
13. Install electrical insulation tape/sleeving on all leads.
14. Label this harness adapter, M548A3 only.
2-32