Remove old emergency relay valve from front Air Reservoir Assembly.
Up
MWO-5-2330-360-23-1 Instructlions for Brake (BENDIX) Modification Manual
Next
Connect Air Chamber Service Hoses and Air Lines

MWO 5-2330-360-23-1
10. MODIFICATION PROCEDURE FOR M870 BRAKE (BENDIX) (Continued).
i.
Install New Emergency Relay Valve PN 104561 on Front Air Reservoir Tank.
NOTE
The new emergency relay valve comes with a new bracket supplied. The bracket will not be
needed for this installation. Dispose of bracket as described in paragraph 8d.
Refer to Figure 7.
(1) Obtain new emergency relay valve, PN 104561.
NOTE
To prevent mixup between valves, before installing new relay valve, check part number of
valve. Both emergency relay valves look identical but have different internal components.
(2) Remove masking tape from threads of pipe nipple (1), reducing bushing (2), two straight adapter (3), top
elbow (4), and tee (5). Thoroughly clean nipple, bushing, two straight adapters, elbow, and tee.