Page Title: Introduction to Quality Assurance
Click here for thousands of PDF manuals
Home
Integrated Publishing
Army Medical Introduction to Quality AssuranceIntroduction to Quality AssuranceDevelopmentAcknowledgementTable of ContentsTable of Contents-cont.IntroductionCredit AwardedLesson AssignmentLesson 1. Quality Assurance and Quality ControlOptimal radiographs.Quality Control SystemFigure 1-2. Sensitometer opened.Figure 1-4. Thermometer.Figure 1-6. Collimator and Beam Alignment Test Tools.Figure 1-8. Star focal spot test tool.Figure 1-9. Tomographic phantoms.Record KeepingExercises, Lesson 1Exercises, Lesson 1-cont.Solutions to Exercises, Lesson 1Lesson AssignmentLesson 2. Federal and Military RegulationsPurchase specification procedures. Standards for image quality.Military Regulations: Technical Bulletin Medical 521Figure 2-1. Technical Bulletin (TB) MED 521.Exercises, Lesson 2Solutions to Exercises, Lesson 2Lesson AssignmentLesson 3. Quality Assurance/Quality Control Monitoring and MaintenanceQA/QC Technician. Exercises, Lesson 3Exercises, Lesson 3-cont.Solution to Exercises, Lesson 3Lesson AssignmentLesson 4. Radiographic Unit Quality Control TestsFigure 4-2. Testing the 60 kVp region.Figure 4-3. Testing 80 kVp region.Figure 4-4. Testing 100 kVp region.Figure 4-5. Testing 120 kVp region.Evaluation and InterpretationSection II. Electronic X-Ray Timing and Milliamperes TestsEquipment/MaterialFigure 4-8. Second exposure.Figure 4-9. Third exposure.Evaluation and InterpretationSection III. Focal Spot Quality Control TestProcedureFigure 4-11. First exposure with small focal spot. Evaluation and InterpretationSection IV. Collimator Quality Control TestFigure 4-14. Collimator test tool with "A" and "F" markers.Figure 4-15. Collimator test tool with room number included.Section V. Automatic Exposure Timer (AET) Quality Control TestReproducibility TestFigure 4-17. Machine factors are set.Figure 4-18. Machine set on normal density.Figure 4-20 (continued). Examples of set up for remaining exposures.Evaluation and InterpretationFigure 4-21. Same set up as the reproducibility test.Figure 4-22. Note the "A" identification marker placed on the phantom prior to the first exposure.Figure 4-23. Set up with markers for 80 through 120.Field Sensitivity Matching TestFigure 4-24. Set up remains the same as in reproducibility test.Density Control Function TestFigure 4-26. Geometry the same as in the reproducibility test.Response Capability TestFigure 4-29. Base section measures only two inches.Figure 4-30. Set up for 80 kVp (base at six inches).Backup Timer SetFigure 4-32. Ready to take AET exposure for backup timer test.Preventive MaintenanceExercises, Lesson 4Exercises, Lesson 4-cont.Exercises, Lesson 4-cont.Exercises, Lesson 4-cont.Exercises, Lesson 4-cont.Exercises, Lesson 4-cont.Exercises, Lesson 4-cont.Solutions to Exercises, Lesson 4Solutions to Exercises, Lesson 4-cont.Solutions to Exercises, Lesson 4-cont.Lesson AssignmentLesson 5. Flouroscopic Unit Quality Control TestsFigure 5-2. Place three-inch metal object on table.Evaluation and InterpretationPreventive MaintenanceSection II. Beam restriction Adequacy TestFigure 5-6. Technologist locating the control dot under the fluoroscope.Perform the beam restriction test in the fluoroscopic modeEvaluation and InterpretationSection III. Focusing and Resolution of the Imaging SystemFigure 5-7. Equipment for focusing and resolution test.Evaluation and InterpretationSection IV. The Exposure Rate TestFigure 5-9. Centering the dosimeter chamber to center of radiation field.Preventive MaintenanceExercises, Lesson 5Exercises, Lesson 5-cont.Exercises, Lesson 5-cont.Exercises, Lesson 5-cont.Exercises, Lesson 5-cont.Exercises, Lesson 5-cont.Solutions to Exercises, Lesson 5Solutions to Exercises, Lesson 5-cont.Lesson AssignmentLesson 6. Tomographic Units Quality Control TestsFigure 6-2. Placing the cassette in the Bucky tray.Evaluation and InterpretationSection II. Exposure Angle TestFigure 6-3. Select the cut level of 12.5 cm.Evaluation and InterpretationSection III. Uniformity of Tomographic Exposure TestProcedureFigure 6-5. Position an 8- x 10-inch cassette in the Bucky tray.Figure 6-7. Cut level indicator set at 12 cm.Evaluation and InterpretationCorrective MaintenanceSection IV. Cut Thickness TestEvaluation and InterpretationFigure 6-9. Test for all section thickness selectionsSection V. Flatness of PlaneFigure 6-10. Cassette is lengthwise in the Bucky tray.Figure 6-12. Test wedge is to center of upper left quadrant.Figure 6-13. Cut level indicator set at 12 cm.Figure 6-14. Placement of tomographic test wedge for remaining field quadrants-cont.Evaluation and InterpretationSection VI. Resolution TestFigure 6-15. Selecting cut level moving up to 10.5 cm.Figure 6-16. Inserting 8- x 10-inch cassette in Bucky tray.Preventive MaintenanceExercises, Lesson 6Exercises, Lesson 6-cont.Exercises, Lesson 6-cont.Exercises, Lesson 6-cont.Exercises, Lesson 6-cont.Solutions to Exercises, Lesson 6Solutions to Exercises, Lesson 6-cont.Lesson AssignmentLesson 7. Processors/Darkrooms Quality Control TestsFigure 7-1. Sensitometer.Figure 7-3. Digital thermometer with metal stem.Procedure-cont.Figure 7-5. Exposed film showing how to use the sensitometer.Evaluation and InterpretationSection II. Automatic Processor Accuracy Test-Daily MaintenanceSection III. Safelight TestEvaluation and InterpretationSection IV. Darkroom Assurance Light Leak TestPreventive MaintenanceExercises, Lesson 7Exercises, Lesson 7-cont.Exercises, Lesson 7-cont.Exercises, Lesson 7-cont.Exercises, Lesson 7-cont.Solutions to Exercises, Lesson 7Solutions to Exercises, Lesson 7-cont.Lesson AssignmentLesson 8. Illuminators Quality Control TestFigure 8-1. First quadrant.Figure 8-2. Second quadrant.Figure 8-4. Fourth quadrant.Corrective MaintenanceExercises, Lesson 8Exercises, Lesson 8-cont.Solutions to Exercises, Lesson 8Lesson AssignmentLesson 9. Cassettes/Intensifying Screens Quality Control TestsFigure 9-1. Densitometer used in making density readings.Evaluation and InterpretationSection II. Film-Screen Contact TestProcedureFigure 9-4. Cassette being tested with paper clips.Corrective MaintenanceExercises, Lesson 9Exercises, Lesson 9-cont.Exercises, Lesson 9-cont.Solutions to Exercises, Lesson 9Lesson AssignmentLesson 10. Grid Alignment Quality Control TestFigure 10-1. Grid alignment test tool at zero position centered.Evaluation and InterpretationCorrective MaintenanceExercises, Lesson 8Solutions to Exercises, Lesson 8Lesson AssignmentLesson 11. Protective Devices Quality Control TestsEvaluation and InterpretationSection II. Protective Devices Quality Control TestOverhead Tube ProcedureFigure 11-2. Test being made of one glove from a pair.Preventive MaintenanceExercises, Lesson 11Exercises, Lesson 11-cont.Exercises, Lesson 11-cont.Solutions to Exercises, Lesson 11Lesson AssignmentLesson 12. Retake Analysis ProgramVarious Methods of Procedural SelectionProcedure-cont.Evaluation and InterpretationFollow-upExercises, Lesson 12Exercises, Lesson 12-cont.Solutions to Exercises, Lesson 12
Army Medical
Introduction to Quality AssuranceIntroduction to Quality AssuranceDevelopmentAcknowledgementTable of ContentsTable of Contents-cont.IntroductionCredit AwardedLesson AssignmentLesson 1. Quality Assurance and Quality ControlOptimal radiographs.Quality Control SystemFigure 1-2. Sensitometer opened.Figure 1-4. Thermometer.Figure 1-6. Collimator and Beam Alignment Test Tools.Figure 1-8. Star focal spot test tool.Figure 1-9. Tomographic phantoms.Record KeepingExercises, Lesson 1Exercises, Lesson 1-cont.Solutions to Exercises, Lesson 1Lesson AssignmentLesson 2. Federal and Military RegulationsPurchase specification procedures. Standards for image quality.Military Regulations: Technical Bulletin Medical 521Figure 2-1. Technical Bulletin (TB) MED 521.Exercises, Lesson 2Solutions to Exercises, Lesson 2Lesson AssignmentLesson 3. Quality Assurance/Quality Control Monitoring and MaintenanceQA/QC Technician. Exercises, Lesson 3Exercises, Lesson 3-cont.Solution to Exercises, Lesson 3Lesson AssignmentLesson 4. Radiographic Unit Quality Control TestsFigure 4-2. Testing the 60 kVp region.Figure 4-3. Testing 80 kVp region.Figure 4-4. Testing 100 kVp region.Figure 4-5. Testing 120 kVp region.Evaluation and InterpretationSection II. Electronic X-Ray Timing and Milliamperes TestsEquipment/MaterialFigure 4-8. Second exposure.Figure 4-9. Third exposure.Evaluation and InterpretationSection III. Focal Spot Quality Control TestProcedureFigure 4-11. First exposure with small focal spot. Evaluation and InterpretationSection IV. Collimator Quality Control TestFigure 4-14. Collimator test tool with "A" and "F" markers.Figure 4-15. Collimator test tool with room number included.Section V. Automatic Exposure Timer (AET) Quality Control TestReproducibility TestFigure 4-17. Machine factors are set.Figure 4-18. Machine set on normal density.Figure 4-20 (continued). Examples of set up for remaining exposures.Evaluation and InterpretationFigure 4-21. Same set up as the reproducibility test.Figure 4-22. Note the "A" identification marker placed on the phantom prior to the first exposure.Figure 4-23. Set up with markers for 80 through 120.Field Sensitivity Matching TestFigure 4-24. Set up remains the same as in reproducibility test.Density Control Function TestFigure 4-26. Geometry the same as in the reproducibility test.Response Capability TestFigure 4-29. Base section measures only two inches.Figure 4-30. Set up for 80 kVp (base at six inches).Backup Timer SetFigure 4-32. Ready to take AET exposure for backup timer test.Preventive MaintenanceExercises, Lesson 4Exercises, Lesson 4-cont.Exercises, Lesson 4-cont.Exercises, Lesson 4-cont.Exercises, Lesson 4-cont.Exercises, Lesson 4-cont.Exercises, Lesson 4-cont.Solutions to Exercises, Lesson 4Solutions to Exercises, Lesson 4-cont.Solutions to Exercises, Lesson 4-cont.Lesson AssignmentLesson 5. Flouroscopic Unit Quality Control TestsFigure 5-2. Place three-inch metal object on table.Evaluation and InterpretationPreventive MaintenanceSection II. Beam restriction Adequacy TestFigure 5-6. Technologist locating the control dot under the fluoroscope.Perform the beam restriction test in the fluoroscopic modeEvaluation and InterpretationSection III. Focusing and Resolution of the Imaging SystemFigure 5-7. Equipment for focusing and resolution test.Evaluation and InterpretationSection IV. The Exposure Rate TestFigure 5-9. Centering the dosimeter chamber to center of radiation field.Preventive MaintenanceExercises, Lesson 5Exercises, Lesson 5-cont.Exercises, Lesson 5-cont.Exercises, Lesson 5-cont.Exercises, Lesson 5-cont.Exercises, Lesson 5-cont.Solutions to Exercises, Lesson 5Solutions to Exercises, Lesson 5-cont.Lesson AssignmentLesson 6. Tomographic Units Quality Control TestsFigure 6-2. Placing the cassette in the Bucky tray.Evaluation and InterpretationSection II. Exposure Angle TestFigure 6-3. Select the cut level of 12.5 cm.Evaluation and InterpretationSection III. Uniformity of Tomographic Exposure TestProcedureFigure 6-5. Position an 8- x 10-inch cassette in the Bucky tray.Figure 6-7. Cut level indicator set at 12 cm.Evaluation and InterpretationCorrective MaintenanceSection IV. Cut Thickness TestEvaluation and InterpretationFigure 6-9. Test for all section thickness selectionsSection V. Flatness of PlaneFigure 6-10. Cassette is lengthwise in the Bucky tray.Figure 6-12. Test wedge is to center of upper left quadrant.Figure 6-13. Cut level indicator set at 12 cm.Figure 6-14. Placement of tomographic test wedge for remaining field quadrants-cont.Evaluation and InterpretationSection VI. Resolution TestFigure 6-15. Selecting cut level moving up to 10.5 cm.Figure 6-16. Inserting 8- x 10-inch cassette in Bucky tray.Preventive MaintenanceExercises, Lesson 6Exercises, Lesson 6-cont.Exercises, Lesson 6-cont.Exercises, Lesson 6-cont.Exercises, Lesson 6-cont.Solutions to Exercises, Lesson 6Solutions to Exercises, Lesson 6-cont.Lesson AssignmentLesson 7. Processors/Darkrooms Quality Control TestsFigure 7-1. Sensitometer.Figure 7-3. Digital thermometer with metal stem.Procedure-cont.Figure 7-5. Exposed film showing how to use the sensitometer.Evaluation and InterpretationSection II. Automatic Processor Accuracy Test-Daily MaintenanceSection III. Safelight TestEvaluation and InterpretationSection IV. Darkroom Assurance Light Leak TestPreventive MaintenanceExercises, Lesson 7Exercises, Lesson 7-cont.Exercises, Lesson 7-cont.Exercises, Lesson 7-cont.Exercises, Lesson 7-cont.Solutions to Exercises, Lesson 7Solutions to Exercises, Lesson 7-cont.Lesson AssignmentLesson 8. Illuminators Quality Control TestFigure 8-1. First quadrant.Figure 8-2. Second quadrant.Figure 8-4. Fourth quadrant.Corrective MaintenanceExercises, Lesson 8Exercises, Lesson 8-cont.Solutions to Exercises, Lesson 8Lesson AssignmentLesson 9. Cassettes/Intensifying Screens Quality Control TestsFigure 9-1. Densitometer used in making density readings.Evaluation and InterpretationSection II. Film-Screen Contact TestProcedureFigure 9-4. Cassette being tested with paper clips.Corrective MaintenanceExercises, Lesson 9Exercises, Lesson 9-cont.Exercises, Lesson 9-cont.Solutions to Exercises, Lesson 9Lesson AssignmentLesson 10. Grid Alignment Quality Control TestFigure 10-1. Grid alignment test tool at zero position centered.Evaluation and InterpretationCorrective MaintenanceExercises, Lesson 8Solutions to Exercises, Lesson 8Lesson AssignmentLesson 11. Protective Devices Quality Control TestsEvaluation and InterpretationSection II. Protective Devices Quality Control TestOverhead Tube ProcedureFigure 11-2. Test being made of one glove from a pair.Preventive MaintenanceExercises, Lesson 11Exercises, Lesson 11-cont.Exercises, Lesson 11-cont.Solutions to Exercises, Lesson 11Lesson AssignmentLesson 12. Retake Analysis ProgramVarious Methods of Procedural SelectionProcedure-cont.Evaluation and InterpretationFollow-upExercises, Lesson 12Exercises, Lesson 12-cont.Solutions to Exercises, Lesson 12
Privacy Statement - Press Release - Copyright Information. - Contact Us