Click here to make tpub.com your Home Page
Page Title: Introduction to Technical Control Part I
Click here for thousands of PDF manuals
Home
Integrated Publishing
Army Communication Systems Introduction to Technical Control Part IIntroduction to Technical Control Part IGeneral General (continued)Table of ContentsTable of Contents (cont)Grading and Certification InstructionsLesson 1. Patching PanelsLearning Event 2: Technical Control FunctionsSubstituting EquipmentFigure 1-1. Relationship Between Technical Control Facility and Patch and Test FacilitiesLearning Event 3: Maintenance ResponsibilitiesLearning Event 4: Patching ArrangementsVoice-Frequency Primary Patch Bay.Voice-Frequency Patching Module.Figure 1-4. Front Panel of Typical VF Primary Bay Patching ModuleVoice-Frequency Patching Module. (Cont)Figure 1-5. Jack Designations in Circuit Diagrams of Patching ModulesFigure 1-6. Lead Designations for LINE-EQ Jack SetInterbay Trunk Module.Figure 1-8. Typical Interbay Trunking Arrangement for VF Primary Patch BaysFigure 1-9. Typical Interbay Trunk Modules Front PanelsMiscellaneous Patching Module.Miscellaneous Patching Module. (Cont)Figure 1-11. Typical VF Patch Bay Miscellaneous Patching ModuleFigure 1-12. Miscellaneous Patching Module - Multiple Jacks and Speaker Jacks Wiring DiagramOther VF Primary Patch Bay ComponentsFigure 1-13. Typical Front Elevations of VF Primary Patch BaysEqual Level Patch Bay.Miscellaneous Patching Modules.Figure 1-14. Typical Miscellaneous Patching Module Front Panel with 6-Way/4-Wire Bridges AppearancesLearning Event 5: DC Circuit AreaInterbay Trunk Modules.Figure 1-16. Low-Speed Digital Circuit Patching ArrangementFigure 1-17. Front Panel of a Typical DC Primary Patch Bay Send or Receive Patching ModuleFigure 1-18. Jack Wiring for Typical SEND Patching Module in DC Primary Patch BayFigure 1-19. Jack Wiring for Typical Receive Patching Module in DC Primary Patch BayFigure 1-20. Front Panel for a Typical Interbay Trunk ModuleFigure 1-21. Wiring for Typical Interbay Trunk ModuleDC Circuit Patch Bay.Interbay Trunk and Miscellaneous Patching Modules.Figure 1-22. Front panel of a Typical Send or Receive Patching Module for DC Circuit Patching BayFigure 1-23. Jack Wiring for Typical Receive Patching Module in DC Circuit Patch Bay (Low-Level)Figure 1-24. Jack Wiring for Typical Send Patching Module in DC Circuit Patch Bay (Low-Level)Circuit Conditioning Bay.Group-Patch Panel.Learning Event 6: Location and ConfigurationsLearning Event 7: Test Instruments Used in Technical Control FacilitiesMost-Often-Used Instruments.Neutral circuit (high level).VU indicator.Other test equipment.Cable fault locator.Lesson 1. CCTM 105-506 ExtractsSection I. GeneralFigure 3. Typical jack strip assemblyFigure 4. A patch panel consisting of several baysGeneral Organization of a Patch BoardFigure 8. How a patch cord worksSection II. WECO ConceptThe WECO RF Patch bayPatching Procedures for RF Patch BayFigure 14. Basic patching proceduresThe WECO VF Patch BayPatching Procedures for VF Patch BayTelephone Mux FailureLine Circuit in TroubleThe WECO DC Patch BayPatching Procedures for the DC Patch BayTeletypewriter Malfunction - Full Duplex CircuitSection 3. ConceptFigure 28. Group panel jack fieldsFigure 31. Typical mux system, receive circuitChannel Modulator/Demodulator Tone Package FailureGroup Demodulator FailureSupergroup Demodulator FailureReceive Hybrid FailureDC Patch BayThe Primary Patch PanelPatching Procedures for VF Patch BayFigure 50. Primary panel jack stripFigure 51. Resoring circuit when a circuit conditioning or signaling device malfunctionsFigure 52. Resoring circuit when inband signal generator or one of the attenuator pads malfunctionsChannel Circuit MalfunctionFigure 54. DC panel jacksTelegraph Mux Channel FailureFigure 58. Replacing a malfunctioning typewriter, half duplexPractice ExercisePractice Exercise (Cont)Practice Exercise (Cont)Practice Exercise (Cont)Practice Exercise (Cont)Practice Exercise (Cont)Practice Exercise (Cont)Answers to Practice ExerciseAnswers to Practice Exercise (Cont)Lasson 1. Patching panelsLesson 2. Line Termination and Distibution FramesFigure 2-1. Vertical Side of CDFFigure 2-2. Vertical Side of CDFLearning Event 2: Main-frame ConstructionsFigure 2-3. Main Distributing Frame, ComponentsProtectors.Figure 2-5. Line Protector and Carbon BlocksDifferences in Types of Main Frames.Figure 2-6. Group of Line ProtectorsCable Characteristics.Color Coding.Color CombinationsLearning Event 4: Wiring RecordsAttachment to Distributing Frame.Cable Forms.Figure 2-7. Single-Leg Cable FormFigure 2-8. Multileg Cable FormFigure 2-9. Typical Installation of Single-Leg Cable Form on Vertical FrameFigure 2-10. Typical Installation of Multileg Cable Form on Horizontal FrameFigure 2-11. Terminating Skinners on LugsIdentification.Cross-Connect Records.Figure 2-12. Distributing Frame Circuit, Simplified DiagramFigure 2-13. Rear View of Patching BaysPractice ExercisePractice Exercise (Cont)Practice Exercise (Cont)Practice Exercise (Cont)Practice Exercise (Cont)Answers to Practice ExerciseLesson 2. Line Termination and Distribution Frames
Army Communication Systems
Introduction to Technical Control Part IIntroduction to Technical Control Part IGeneral General (continued)Table of ContentsTable of Contents (cont)Grading and Certification InstructionsLesson 1. Patching PanelsLearning Event 2: Technical Control FunctionsSubstituting EquipmentFigure 1-1. Relationship Between Technical Control Facility and Patch and Test FacilitiesLearning Event 3: Maintenance ResponsibilitiesLearning Event 4: Patching ArrangementsVoice-Frequency Primary Patch Bay.Voice-Frequency Patching Module.Figure 1-4. Front Panel of Typical VF Primary Bay Patching ModuleVoice-Frequency Patching Module. (Cont)Figure 1-5. Jack Designations in Circuit Diagrams of Patching ModulesFigure 1-6. Lead Designations for LINE-EQ Jack SetInterbay Trunk Module.Figure 1-8. Typical Interbay Trunking Arrangement for VF Primary Patch BaysFigure 1-9. Typical Interbay Trunk Modules Front PanelsMiscellaneous Patching Module.Miscellaneous Patching Module. (Cont)Figure 1-11. Typical VF Patch Bay Miscellaneous Patching ModuleFigure 1-12. Miscellaneous Patching Module - Multiple Jacks and Speaker Jacks Wiring DiagramOther VF Primary Patch Bay ComponentsFigure 1-13. Typical Front Elevations of VF Primary Patch BaysEqual Level Patch Bay.Miscellaneous Patching Modules.Figure 1-14. Typical Miscellaneous Patching Module Front Panel with 6-Way/4-Wire Bridges AppearancesLearning Event 5: DC Circuit AreaInterbay Trunk Modules.Figure 1-16. Low-Speed Digital Circuit Patching ArrangementFigure 1-17. Front Panel of a Typical DC Primary Patch Bay Send or Receive Patching ModuleFigure 1-18. Jack Wiring for Typical SEND Patching Module in DC Primary Patch BayFigure 1-19. Jack Wiring for Typical Receive Patching Module in DC Primary Patch BayFigure 1-20. Front Panel for a Typical Interbay Trunk ModuleFigure 1-21. Wiring for Typical Interbay Trunk ModuleDC Circuit Patch Bay.Interbay Trunk and Miscellaneous Patching Modules.Figure 1-22. Front panel of a Typical Send or Receive Patching Module for DC Circuit Patching BayFigure 1-23. Jack Wiring for Typical Receive Patching Module in DC Circuit Patch Bay (Low-Level)Figure 1-24. Jack Wiring for Typical Send Patching Module in DC Circuit Patch Bay (Low-Level)Circuit Conditioning Bay.Group-Patch Panel.Learning Event 6: Location and ConfigurationsLearning Event 7: Test Instruments Used in Technical Control FacilitiesMost-Often-Used Instruments.Neutral circuit (high level).VU indicator.Other test equipment.Cable fault locator.Lesson 1. CCTM 105-506 ExtractsSection I. GeneralFigure 3. Typical jack strip assemblyFigure 4. A patch panel consisting of several baysGeneral Organization of a Patch BoardFigure 8. How a patch cord worksSection II. WECO ConceptThe WECO RF Patch bayPatching Procedures for RF Patch BayFigure 14. Basic patching proceduresThe WECO VF Patch BayPatching Procedures for VF Patch BayTelephone Mux FailureLine Circuit in TroubleThe WECO DC Patch BayPatching Procedures for the DC Patch BayTeletypewriter Malfunction - Full Duplex CircuitSection 3. ConceptFigure 28. Group panel jack fieldsFigure 31. Typical mux system, receive circuitChannel Modulator/Demodulator Tone Package FailureGroup Demodulator FailureSupergroup Demodulator FailureReceive Hybrid FailureDC Patch BayThe Primary Patch PanelPatching Procedures for VF Patch BayFigure 50. Primary panel jack stripFigure 51. Resoring circuit when a circuit conditioning or signaling device malfunctionsFigure 52. Resoring circuit when inband signal generator or one of the attenuator pads malfunctionsChannel Circuit MalfunctionFigure 54. DC panel jacksTelegraph Mux Channel FailureFigure 58. Replacing a malfunctioning typewriter, half duplexPractice ExercisePractice Exercise (Cont)Practice Exercise (Cont)Practice Exercise (Cont)Practice Exercise (Cont)Practice Exercise (Cont)Practice Exercise (Cont)Answers to Practice ExerciseAnswers to Practice Exercise (Cont)Lasson 1. Patching panelsLesson 2. Line Termination and Distibution FramesFigure 2-1. Vertical Side of CDFFigure 2-2. Vertical Side of CDFLearning Event 2: Main-frame ConstructionsFigure 2-3. Main Distributing Frame, ComponentsProtectors.Figure 2-5. Line Protector and Carbon BlocksDifferences in Types of Main Frames.Figure 2-6. Group of Line ProtectorsCable Characteristics.Color Coding.Color CombinationsLearning Event 4: Wiring RecordsAttachment to Distributing Frame.Cable Forms.Figure 2-7. Single-Leg Cable FormFigure 2-8. Multileg Cable FormFigure 2-9. Typical Installation of Single-Leg Cable Form on Vertical FrameFigure 2-10. Typical Installation of Multileg Cable Form on Horizontal FrameFigure 2-11. Terminating Skinners on LugsIdentification.Cross-Connect Records.Figure 2-12. Distributing Frame Circuit, Simplified DiagramFigure 2-13. Rear View of Patching BaysPractice ExercisePractice Exercise (Cont)Practice Exercise (Cont)Practice Exercise (Cont)Practice Exercise (Cont)Answers to Practice ExerciseLesson 2. Line Termination and Distribution Frames
Privacy Statement - Press Release - Copyright Information. - Contact Us