Chapter 5. ORGANIZATIONAL MAINTENANCE INSTRUCTIONS
Up
TM-32-5985-342-14-P Antenna Tower TS-9A Manual
Next
Figure 5-1. TS-9A Antenna Tower Lubrication

TM 32-5895-342-14&P
Section II. REPAINTING AND REFINISHING INSTRUCTIONS
responsible for painting, maintenance, and preservation
5-3 REPAINTING AND REFINISHING.  TB 43-0118,
of the Antenna Tower TS-9A. SB 11-573, Painting and
Field  Instructions  for  Painting  and  Preserving
Preservation Supplies Available for Field Use for
Electronics Command Equipment Including Camouflage
Electronics Command Equipment, specifies paints and
Pattern Painting of Electrical Equipment Shelters,
preservatives available for maintenance of the tower.
provides  instructions  for  maintenance  personnel
Section III. LUBRICATION INSTRUCTIONS
5-4 GENERAL. Keep all lubricants in closed containers
Table 5-3. Recommended Lubricants for Electric
and store in a clean, dry and cool area. Do not allow
dust, dirt, or other foreign material to mix with oils and
Hoist
grease.  Keep all equipment clean and ready to use.
Keep all external parts that do not require lubrication
Lubricant viscosity group
free of lubricants.
Before application, wipe all
Ambient temperature  Up to 300 rpm  Over 300 rpm
lubrication points free of dirt and grease.  Clean all
-65配o 0蚌*
318.59
-
lubrication  points  after  application  to  prevent
-45配o +20蚌*
318.60
318.59
accumulation of foreign matter. Service the lubrication
-5配o +550 F*
318.61
318.60
points at proper intervals, as illustrated in figures 5-1
+15配o +110蚌
318.62
318.62
through 5-5 and in accordance with the special
+100配o +165蚌
318.63
318.63
instructions contained in paragraph 5-5.
Viscosity
59
60
61
62
63
group 318
5-5 ELEVATOR HOIST. Lubricate the electric elevator
Mobil Oil Co.
HD90
600W
hoist in accordance with the following instructions and
Avrex
903
as illustrated in figure 5-3.
Mobil Fluid
423
Extra Helco
Super
a. Remove red oil level plug and check gearcase
cylinder
for proper oil level. If low, fill with oil through one -of the
upper openings until oil reaches oil level hole. Replace
* For temperatures below + 100 F, special oil seals are
plug tightly.  (Refer to table 5-3 for recommended
required.
lubricants.)
**All group 63 lubricants must be changed after 300
b. Change gearcase lubricant after first 250 hours
hours of high temperature operation.
of use with grease (Mobil-Temp 78). Thereafter, change
the lubricant every 1,500 hours of operation.