![]() ![]() TM 11-5985-371-12&P
Table 4-2. Organizational Troubleshooting - Continued
Malfunction
Test or Inspection
Corrective Action
Use the multimeter to measure the resistance between the two antenna
Step 5.
on the balun and the
wires
removed from one antenna connector
not removed) from the other connector
of the
two antenna wires
balun. Normal reading is 600 ohms.
If normal, go to step 6.
If abnormal, go to step 7.
Check for continuity of each of the two antenna wires
. That is,
Step 5.
use the multimeter to check for continuity (less than 1 ohm) between
the two ends of the antenna wire removed from one antenna connector
Repeat the measurement for the antenna wires connected to the
q
other connector
, after disconnecting the wires.
If normal, reconnect the rf cable and antenna wires.
If abnormal, replace both antenna wires (para 4-16).
4-14
|
|