Page Title: Table 4-1. Organizational Preventive Maintenance Checks and Services - Continued
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Back
Table 4-1. Organizational Preventive Maintenance Checks and Services
Up
TM-11-5985-371-12-P Antenna AS-3577/GRC (NSN 5985-01-148-1778) Manual
Next
Table 4-1. Organizational Preventive Maintenance Checks and Services - Continued

TM 11-5985-371-12&P
Table 4-1. Organizational Preventive Maintenance Checks and Services - Continued
M - Monthly
W - Weekly
D - Daily
Equipment Not
I
Ready/Available
Item to be Inspected
Item
Interval
If:
Procedure
No.
D
W
M
·
Bolts, wingnuts,
Mounting hardware.
3
Check the bolts, washers, wingnuts
or clamps loose
.
or dirty.
and clamps
securing the balun
to the mast
to assure they are clean,
intact, and not loose fitting.
tighten, or replace.
·
Connectors loose
Rf cable connector, balun, and antenna wire
4
or dirty.
connectors.
Insure that the rf cable
and antenna
wire connections
at the balun are
clean, intact, and not loose fitting.
Clean, tighten connectors.
~
·
Terminating resistor box connectors and
5
antenna wire.
Untie the halyard
from the cleat
on the balun
and lower the terminating
resistor box to the ground.
4-8