![]() ![]() TM 11-5985-371-12&P
NOTE
Advise the radio operator prior to and after performing PMCS.
M - Monthly
w - Weekly
D - Daily
Equipment Not
Ready/Available
Item to be Inspected
Item
Interval
If:
Procedure
DWM
No.
WARNING
If the antenna is connected to a trans-
mitter, make certain the transmitter
is not transmitting and will not be
"turned on" prior to entering the area
bounded by the safety area rope.
Installation.
1
·
Check that the antenna is properly in-
stalled (para 2-5).
·
Ropes frayed,
Ropes.
2
cut, or sagging.
Check the 12 guys
, halyard
,
safety area rope
and lanyards
for damage such as cuts, frays, and for
strain. Observe their general appear-
ance for serviceability. Replace
unserviceable ropes.
|
|