Removal of Guys, Guy Stakes, and Halyard.
Up
TM-11-5985-371-12-P Antenna AS-3577/GRC (NSN 5985-01-148-1778) Manual
Next
Strong Winds.

TM 11-5985-371-12&P
(3) Disconnect the pulley snaphook
from the top guy plate
. Coil and
bind the halyard
.
h. Removal of Terminating  Resistor  Stop.
and separate the
Remove the four wingnuts
and terminating
terminating resistor stop
from the mast
resistor stop clamp
on the ter-
Replace the four wingnuts
minating  resistor stop
.
i. Disassembly of Mast.
(1) Remove the insulator from the mast base. (See illustration on page 2-8).
(2) Separate the 16 mast sections and the three guy plates.
(3) Pull the mast base from the ground. Remove the support plate.
j. Packing Carrying Frame and Carrying Case. See section VI, chapter 4.
OPERATION UNDER UNUSUAL CONDITIONS
Section III.
2-7. Sandy or Marshy Terrain.
If the ground in which the
mast base, guy stakes, and
antenna rods are to be
inserted is sandy or marshy,
get specific instructions
from your supervisor on how
to reinforce the mast base
and stakes.  The guy stakes
may be reinforced by driving
the four guy stakes into the
ground at least 2 inches
below the surface and burying
the three guys connected to
each guy stake in the ground.