Click here to make tpub.com your Home Page

Page Title: Pulsing Circuit Test
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Back
Homing Circuit Test
Up
TM-11-5821-284-34 Blade Antenna AS-2285/ARC (NSN 5821-00-054-6374) and AS-2285/ARC (NSN 5821-01-003-0632) Manual
Next
Test  Connections and Conditions

TM 11-5821-284-34
Test equipment
Performance
Step
control settings
Figure ref.
Test procedure
standard
2
Same as step 1.
Measure with ME-26B/U
+6. 2 Vdc. 5%
for +6. 2 Vdc at pin 5
of circuit board Al.
3
Same as step 1.
Measure with ME-26B/U
+13. 7 Vdc t5%
for + 13. 7 Vdc at
A1AR1-10.
4
Same as step 1.
Measure with Ml'-2biB/U
+5. 1 Vdc. -5%
for +5. 1 Vde at pin 8 of
circuit board A;
Figure 5-3. Test connections, receive/transmit logic and homing circuit tests.
Figure 5-4. Test connections, power supply test.
5-11.
Pulsing Circuit Test
a.  Test Equipment.
(1) Test Set, Antenna AN/ARM-115.
(2) Oscilloscope, AN/USM-281.
(3) Power Supply.
b.  Test Connections and Conditions. Connect equipment as shown in figure 3-2. Connect positive lead of 100
MV OUTPUT to FL1 and negative lead to FL5. Turn on the equipment and allow 5-minuite warmup before proceeding.
c.  Procedure
Test equipment
Performance
Step
control settings
Figure ref.
Test procedure
standard
Fig. 56 6Q
1
AN/ARM-115:
Manually trip limit switch
Waveform is same as that
METER FUNCTION: +0
and 5-10 (TP-1)
S1 and observe wave
shown in figure 6-4A.
to 500 mV.
form at A1AR1-9
MV ADJUST: Adjust
for +100 mV.
MANUAL TUNE:, OFF.
AN/USM-281 :Adjust
controls to observe
waveforms shown in
figures 64A and 6-4B.
Power Supply. Adjust for
+27. 5 Vdc.
2
Same as step 1 except
With limit switch S1 still
Waveform is same as that
set AN/ARM-115
and 5-10 (TP-1)
tripped, observe wave-
shown In figure 64B.
METER FUNCTION to
form ;it 41 R1--9
-0 to 600 mV and adjust
for -100-mV output.
(3) Oscilloscope, AN/USM-281.
5-12.
Sequencing Circuit Test
(4) Generator, RF Signal AN/USM-44A.
a.  Test Equipment.
(5) Amplifier, Power Boonton 230A.
(1) Test Set, Antenna AN/ARM-115.
(2) Multimeter ME-26B/U.
5-5