TM 1-1520-238-T-6 9–58 9–2. LOCATION AND DESCRIPTION OF MAJOR COMPONENTS (cont) 9–2 (11)   CPG station dc emergency bus 3 circuit protection. NOTE Refer to CPG station (fig. 9–47) for configuration and component locations. 1. CPG  CIRCUIT  BREAKER  PANEL  1 M69-252 1 Figure  9–47. CPG Station Table 9–23 contains a listing of the circuit breakers associated with the CPG station dc emergency bus, along with each circuit breaker’s rating in amps. Table   9–23. CPG Station DC Emergency Bus Circuit Protection CPG Circuit Breaker Panel 1 (fig. 9–48) CB NO. CB NAME RATING CB13 EMERG BATT ICS 5 amp CB29 EMERG BATT CAUT 7.5 amp CB30 EMERG BATT UTIL SEC LT 5 amp CB31 EMERG BATT ENG INST 10 amp CB32 EMERG BATT VHF AM/FM 5 amp