TM 1–1520–238–T–3 3–30 Change 4 3–130    SIGNAL NAME: TURN RATE FAIL (ACY) TURNRATE IND STAT (ACZ) MEMORY LOCATION:    002110 MEMORY DATA BIT(S): 18 (BINARY) CONDITION: (None) SIGNAL FUNCTION: Indicates turn rate indicator is properly controlled by DASEC. REMARKS:   From DASEC to FCC. PASS: If first digit displayed on HOD is 0 and HARS malfunctions exist refer to Chapter 6, paragraph 6–13. If no HARS malfunctions have been identified, replace DASEC (TM 1–1520–238–23). FAIL:    Location of fault: video display unit (VDU), wiring from VDU to DASEC, DASEC. Troubleshoot wiring to isolate fault (TM 1–1520–238–T–7).