Order this information in Print

Order this information on CD-ROM

Download in PDF Format

     

Click here to make tpub.com your Home Page

Page Title: COLL ACT FAIL (ACY) CLTV ACTR STAT (ACZ)
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive

Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

Back
HARS FAIL (ACY) HARS TEST STAT (ACZ)
Up
TM-1-1520-238-T-3 Army Model AH-64 Helicopter (NSN 1520-01-106-9519) (EIC: RHA) Multiplex Read Codes Manual
Next
BUCS TRACER FAIL (ACY) BUCS TRACER STAT (ACZ)

TM 1–1520–238–T–3 3–22 Change 4 3–95    SIGNAL NAME: COLL ACT FAIL (ACY) CLTV ACTR STAT (ACZ) MEMORY LOCATION:    002106 MEMORY DATA BIT(S): 13 (BINARY) CONDITION: (None) SIGNAL FUNCTION: Indicates capability of collective (vertical) servoactuator to respond correctly to DASEC commands. REMARKS:   From DASEC to FCC. PASS: If third digit displayed on HOD is 0, go to paragraph 3–96. FAIL:    Location of fault: collective (vertical) servoactuator, wiring from collective (vertical) servoactuator to DASEC. Troubleshoot wiring to isolate fault (TM 1–1520–238–T–7). 3–96    SIGNAL NAME: ASE CONTROL PANEL FAIL (ACY) ASE CONT PNL STAT (ACZ) MEMORY LOCATION:    002106 MEMORY DATA BIT(S): 14 (BINARY) CONDITION: (None) SIGNAL FUNCTION: Indicates capability of all control panel switches to function properly. REMARKS:   From DASEC to FCC. PASS: If second digit displayed on HOD is 0, 1, 2, or 3, go to paragraph 3–97. FAIL:    Location of fault: ASE control panel, wiring from ASE control panel to DASEC. Troubleshoot wiring to isolate fault (TM 1–1520–238–T–7). 3–97    SIGNAL NAME: 26 VAC A FAIL (ACY) 26VAC XFMR1 STAT (ACZ) MEMORY LOCATION:    002106 MEMORY DATA BIT(S): 16 (BINARY) CONDITION: (None) SIGNAL FUNCTION: Indicates status of 26 VAC A output from transformer T1. REMARKS:   From DASEC to FCC. PASS: If second digit displayed on HOD is 0 or 2, go to paragraph 3–98. FAIL:    Location of fault: Transformer 1 (T1) or, on aircraft serial effectivity numbers 88–0199 and subsequent, replace transformer/filter assembly (TM 1–1520–238–23). 3–98    SIGNAL NAME: 26 VAC B FAIL (ACY) 26VAC XFMR2 STAT (ACZ) MEMORY LOCATION:    002106 MEMORY DATA BIT(S): 17 (BINARY) CONDITION: (None) SIGNAL FUNCTION: Indicates status of 26 VAC B output from transformer T2. REMARKS:   From DASEC to FCC. PASS: If second digit displayed on HOD is 0, 1, 2, or 3, go to paragraph 3–99. FAIL:    Location of fault: Transformer 2 (T2) or, on aircraft serial effectivity numbers 88–0199 and subsequent, replace transformer/filter assembly (TM 1–1520–238–23). 3–99    SIGNAL NAME: 28 VDC BUCS FAIL (ACY) 26VDC BUCS STAT (ACZ) MEMORY LOCATION:    002106 MEMORY DATA BIT(S): 18 (BINARY) CONDITION: (None) SIGNAL FUNCTION: Indicates status of 28 VDC BUCS power. REMARKS:   From DASEC to FCC. PASS: If first digit displayed on HOD is 0 or 1, go to paragraph 3–100. FAIL:    Location of fault: BUCS circuit breaker, wiring from circuit breaker to DASEC, DASEC. Troubleshoot wiring to isolate fault (TM 1–1520–238–T–7).

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing