TM-1-1520-238-T-3 Army Model AH-64 Helicopter (NSN 1520-01-106-9519) (EIC: RHA) Multiplex Read Codes Manual
Next
Figure  1–2. CPG Data Entry Keyboard (ADC) and CDU (ADD)

TM 1–1520–238–T–3 1–8 1–12 REMARKS. REMARKS  provide  signal  path  information  which  is  useful  in  determining  possible  fault  locations  during troubleshooting. EXAMPLE: REMARKS:   From DEK through CPG MRTU Type III to FCC. Selects operating mode for fire control system. 1–13 PASS. PASS provides fault isolation and troubleshooting actions to be performed, references to other failure symptom paragraphs  within  TM 1–1520–238–T–3,  references  directing  you  to  return  to  the  respective  chapter  failure symptom index within TM 1–1520–238–T–3 and to perform the next sequential failure symptom paragraph, and references to technical manuals if the required CONDITION is met. Direct read codes are presented when possible to reduce conversion time. Numbers not identified indicate a failure. EXAMPLE: PASS: If CONDITION corresponds to proper mode for switch selected, go to paragraph 17–3. 1–14 FAIL. FAIL provides location of fault and troubleshooting actions to be performed, references to other failure symptom paragraphs,  references  to  the  failure  symptom  index  and  next  failure  symptom  paragraph,  references  to  other chapters and paragraphs, and references to technical manuals if the required CONDITION is not met. Faults are listed in the most probable failure sequences. ALWAYS troubleshoot wiring to isolate fault first, then replace LRU in the order given, unless a direct replacement is indicated. EXAMPLE: FAIL:    Location of fault: DEK, wiring from DEK to CPG MRTU Type III, CPG MRTU Type III. Troubleshoot wiring to isolate fault (TM 9–1230–476–20–2). 1–15 MULTIPLEX READ CODES INTERPRETATION PROCEDURE. a. Check entry from log book failure symptom; RANGE DATA CANNOT BE DISPLAYED. b. Go to TM 1–1520–238–T–2 (Integrated Troubleshooting Master Failure Symptom Index) for appropriate MOC. c. Perform MOC. d. Go to TM 1–1520–238–T–3, Chapter 17. e. Go to FAILURE SYMPTOM INDEX in Chapter 17. FAILURE SYMPTOM INDEX Symptom Refer to paragraph DATA ENTRY KEYBOARD NO-GO CPG COMPARTMENT   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .     17–1 KEYBOARD FAILED DISPLAYED ON ORT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .     17–1 RANGE DATA CANNOT BE DISPLAYED   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .     17–2 f. Go to failure symptom paragraph 17–2 referenced in FAILURE SYMPTOM INDEX, as an aid in locating fault.

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing