Order this information in Print

Order this information on CD-ROM

Download in PDF Format

     

Click here to make tpub.com your Home Page

Page Title: Section II. MULTIPLEX READ CODE INTERPRETATIONS
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive

Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

Back
Section  I.    GENERAL INFORMATION
Up
TM-1-1520-238-T-3 Army Model AH-64 Helicopter (NSN 1520-01-106-9519) (EIC: RHA) Multiplex Read Codes Manual
Next
Figure  1–1. TADS Optical Relay Tube (ORT) (ADC)

TM 1–1520–238–T–3 Change 5 1–3 Section  II.    MULTIPLEX READ CODE INTERPRETATIONS NOTE Multiplex  read  codes  are  observed  on  the  HOD  (ADC)  or CDU (ADD). 1–6    FAILURE SYMPTOM PARAGRAPH. Multiplex  read  codes  are  interpreted  through  the  use  of  failure  symptom  paragraphs.  (See  Example.)  Failure symptom paragraphs provide information which can be used in locating failures with multiplex read codes during a Maintenance Operational Check (MOC). Failure symptom paragraphs specify a known or expected aircraft MOC CONDITION and the corresponding SIGNAL NAME, MEMORY LOCATION to be examined and MEMORY DATA BITS being examined in the MEMORY LOCATION. Comparing the aircraft CONDITION with the displayed multiplex read code response allows fault isolation through the use of information presented under SIGNAL FUNCTIONS, REMARKS, PASS and FAIL. EXAMPLE: 17–2   SIGNAL NAME:    DEK SWITCH MEMORY LOCATION:   000444 MEMORY DATA BIT(S):    8–11    (HEX) CONDITION:    If fourth digit displayed on HOD is 0=STBY. If fourth digit displayed on HOD is 1=RANGE. If fourth digit displayed on HOD is 2=FD/LS. If fourth digit displayed on HOD is 3=(NOT USED). If fourth digit displayed on HOD is 4=TGT. If fourth digit displayed on HOD is 5=CODE. If fourth digit displayed on HOD is 6=SP1. If fourth digit displayed on HOD is 7=OFF. SIGNAL FUNCTION:    Monitors position of DEK DATA ENTRY switch. REMARKS:   From DEK through CPG MRTU Type III to FCC. Selects operating mode for fire control system. PASS:    If CONDITION corresponds to proper mode for switch selected, go to paragraph 17–3. FAIL:   Location of fault: DEK, wiring from DEK to CPG MRTU Type III, CPG MRTU Type III. Troubleshoot wiring to isolate fault TM 9–1230–476–20–2. 1–7    SIGNAL NAME. The SIGNAL NAME is the common or abbreviated name for an input or output. EXAMPLE: 17–22   SIGNAL NAME:    DEK SWITCH Abbreviations and acronyms can be found in the List of Abbreviations located in the Glossary. 1–8    MEMORY LOCATION. The MEMORY LOCATION is the octal address of the signal name data you are going to inspect. EXAMPLE: MEMORY LOCATION:   000444 1–9    MEMORY DATA BITS. a. Memory  data  indicates  the  bit(s)  to  be  examined  in  a  16-bit  word.  These  bits  are  used  by  the  fire  control computer (FCC) to determine the status of system/Line Replaceable Units (LRU). The numbers to the right of the memory location on the HOD are memory data octal representations. Multiplex read code responses are read from right to left. See Figure 1–1 (ADC) and Figure 1–1.1 (ADD).

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing