3–1 SYSTEMS – POWER–UP (cont)
Up
TM-1-1520-238-T-1 Helicopter Attack AH-64A Apache (NSN 1520-01-106-9519) (EIC: RHA) Manual
Next
3–2 SYSTEMS – POWER DOWN

TM 1–1520–238–T–1 Change 4 3–9 3–1 SYSTEMS – POWER–UP (cont) 3–1 NOTE When GEN 1, GEN 2 and EXT PWR indicators on the pilot caution/warning panel (fig. 2–20) light at the same time, the indication means external power is applied and generator 1 and generator 2 are off–line. 9.  Verify the GEN 1, GEN 2, and EXT PWR indicators on pilot caution/warning panel are lit. 10.  Verify the HOT RECT 1, HOT RECT 2, RECT 1, and RECT 2 indicators on pilot caution/warning panel are not lit. 11.  If HOT RECT 1, HOT RECT 2, RECT 1, or RECT 2 indicators on pilot caution/warning panel light, power down aircraft (paragraph 3–2). 12.  Proceed with applicable FD/LS check or maintenance task as required. END OF TASK