Back Figure 9. Inspection Area No. 8 (Sheet 1 of 2) | Up TM-1-1520-238-PMS 10 Hour /14 Day Inspection Checklist for Army
AH-64 Helicopter Manual | Next Figure 9. Inspection Area No. 8 (Sheet 2) |
FOD REMINDER
Check work area for tools and parts after completion of maintenance and inspection
TM 1-1520-238-PMS
67
Seq.
No.
Location
Item and Procedure
MAIN ROTOR MAST
POWER OFF
WARNING
The IR jammer will be dangerously hot following flight operation.
8.1
1
IR Jammer
Physical damage and mounting security
8.2
2
Air Data Sensor
Distortion, corrosion, and mounting security
Upper adapter for cracks
8.3
3
DEICING DISTRIBUTOR
DISTORTION, CRACKS, CORROSION, AND MOUNTING SECURITY
DEICING CABLES FOR CHAFING OR DAMAGED INSULATION AND CONNECTION SECURITY
|