AFTER STARTING APU (CONT)
Up
TM-1-1520-238-MTF Maintenance Test Flight Manual Helicopter Attack AH-64A Apache
Next
STARTING ENGINES – PILOT

TM 1-1520-238-MTF 2-55 PROCEDURE TROUBLESHOOTING REFERENCE AFTER STARTING APU (CONT) e.   NO. 1 PWR lever – LOCKOUT. Verify fuel flows from overboard drain. CAUTION To  prevent  FIRE  BTL  activation,  verify FIRE BTL Select switches are centered. f.   Pilots ENG 1 FIRE PULL handle – Pull. ENCU shuts down, cooling louvers close, fuel flow stops, and respective engine FUEL PSI caution/warning illuminates. g.   Pilots ENG 1 FIRE PULL handle – In. Verify ENCU returns, cooling louvers open, fuel flow returns, and respective engine FUEL PSI caution/warning extinguishes. h.   CPGs ENG 1 FIRE PULL handle – Pull. Verify same function as step f. i.   CPGs ENG 1 FIRE PULL handle – In. Verify same function as step g. j.   NO. 1 PWR lever – OFF. Verify fuel flow stops. k.   Repeat steps e through j using NO. 2 PWR lever and ENG 2 FIRE PULL handles.

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing