TM 1-1520-238-MTF 2-51 Change 4 PROCEDURE TROUBLESHOOTING REFERENCE AFTER STARTING APU (CONT) (4)   BUCS TST switch – CPG and hold. BUCS ON caution light should go out in approximately 20 seconds. Release switch and wait 15 seconds to see if the BUCS FAIL warning light illuminates, if not proceed to step (5). (5)   BUCS select trigger switch (CPG) – Press. Verify illumination of BUCS FAIL warning light in both crew stations. (6)   Collective – full down. (7)   RTR BK switch – As desired. d.   Collective friction – Check as follows: (1)   Pilot and CPG friction – Set at zero. (2)   With spring scale at head of pilots collective, check for breakaway of 4 to 6 pounds.